Hi there,
We are upgrading from 4.3.1 to 5.2.3. We use MIMSJ for our connector applications on Mincom TP. When we initialise our object, we send the parameter to connect TP. We currently initialise MIMSJ with a CONNECT_TPNET like this...
Hi,
We're upgrading MIMS 4.3.1 to Ellipse 5.2.3, and carrying most user exits forward. We were only using terminal interface for MIMS, and so had not implemented any of the user exits at the object level. Where we were using BOC, we are embedding the user exit logic in the application that...
Hi,
We're upgrading from 4.3.1 to 5.2.3 in the next few months. Given that the organisation has Active Directory in place, I am surprised that our sys admins are still debating Unix vs Ellipse authentication. I'm pretty tired of MIMS authentication being thought of as distinct from the...
Hi,
We are looking at hving to update our Equipment Profiles (EGI-Component-Modifier build), and this will involve adds and deletes. We have about 100,000 records to update. There are no useful search criteria on the MSO's, so for each EGI we have to step through screens. Our guesstimate is...
Hi,
Has anyone successfully got 2 applications running on the same machine that both use the MSO object? The BOC doco says that you need to set a Shared Connection parameter prior to doing a connect, but this doesn't seem to help.
Any ideas?
Steve
Hi,
Has anyone got the Delete method of the STDTEXT object working in BOC? We are just getting an error and it shouldn't be that hard...we can create, retrieve std text with no problems.
MyBlock = mobjMIMS.MIMSConnector.Blocks.[New]("MyBlock")
ExtendedDescription =...
Hi,
We've been playing with BOC for a while now, using both the objects (mmm...objects) and the MSO interface. We have recently come across an issue where when we attempt to write to a protected field on a screen, there is no error or warning, so it looks like the field will be updated, but the...
Does anyone have either
- some good documentation, or
- some nice VB code
that explains the StdText object? The supplied doco is a bit vague and the only sample is in delphi. We are trying to append extended text to work orders.
Thanks,
Steve
Hi all,
I'm having terrible trouble trying to install OE and Connector so that it works reliably. It works for a bit, then I get an error in asia32.exe ("referenced memory cannot be read"). It does work on some PC's, but it took a few goes.
The installation I am doing goes like...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.