CS1000, Rls7.5, all phones are DHCP all same node. After a power outage in one of our buildings all of the IP 2001's and 1110e's went down and stayed down. Then it spread to the rest of our system and 2001's and 1110e's in other buildings went down. They all say DHCP Parse Error, DHCP server...
Is Site Manager 15.7.1 backwards compatible with a Nortel ASN router running 15.5.1.1? 15.7.1 is the only version I can find on the Avaya site but documentation does not mention backwards compatibility.
We are replacing PRI's with IP Flex. The IP Flex will give us a presence in other states. Customers call a local number in their state (555-444-3333) and we recieve the call on our IP Flex, 4 digit did (3333) that I will route to our operator. We can make local calls back to that state through...
I changed the ip address, subnet mask, and default gateway on a BCM50e Rls 1. I rebooted, the new address was applied, the OAM port still works, and all other functions work, but the status light is now red. How can I get that light to turn off?
I've backed up Option 11 systems to my laptop with load 143 for example :
>LD 143
CCBR000
.XBK
INFO:NAME FILE
SIZE = 218880 bytes
R>OK.XVR
R>CCCCOK.
But how do you back up an Option 11 , Rls 18 that doesn't have LD 143 or a pc card slot ? I've seen a thread that says to use BKO in LD 43 but...
I have a customer that does not want to send CLID . When I go to
LD 15
CHG
NET_DATA
CLID NO
I reply no to CLID prompt , but the switch still sends the number . If I try to delete a CLID entry
LD 15
CHG
CLID YES
ENTRY X1
ENTRY 1 DELETED !
ENTRY
BUG481
I get this BUG481 code and the...
I have a SL1 switch , with a SL1 phone
TGAR 0
NCOS 6
CLS UNR CFXA
Key 00 SCR XXXX DID
Key 06 CFW 12
When we forward to an external local number (9 XXX XXXX) sta to sta calls will forward . External calls coming in on the DID get a pause and then a fast busy . WE can call this number directly...
I have an 8x24 , Centrex software , ports 101 - 112 equipped and working . I tried to add 8 new phones but they would never sync up , just flash forever . I can get on ports 101 - 112 with one of my new phones and it will sync up , but when I try 113 - 124 it will not sync up . I have replaced...
On an Option 11C , if power goes out , and then comes back on , switch comes back on , but Meridian Mail will not come back on until I go to LD 48 , ENL AML 9 ACMS . Is this normal ? Is there a command that will bring Meridian Mail back up automatically after a power outage ?