  1. chrismec

    SV9100 One-Touch Character/Digit Limit of 24

    Hi all, I have run into a situation where I need a one touch or speed dial or other way, to dial a 45+ long digit number. On the SV9100 there is a 24 character limit on most things it seems. Breaking the dial over two buttons is an option and works, but is not ideal. Is there anyway to chain...
  2. chrismec

    SV9100 Digital Extension Call Recording

    Hello all, am looking for a stand alone call recording solution that is compatible with NEC digital phones. Not looking to record ip phones, only digital phones and maybe analog. NEC has a MyCalls Call Recorder but not sure how integrating that system is into the whole univerge universe. Am...
  3. chrismec

    SV9100 w/ CCIS - Access a trunk line at a different site?

    Hello all, we have several SV9100 system networked via CCIS. At each site, there is a piece of equipment that interfaces via trunk line, that needs to be accessible throughout the network. Preferably these individual trunk lines would be accessible via a regular extension number, but if that is...
  4. chrismec

    SV9100 - Make extension unavailable via auto attendant

    Hi all, is it possible to block some extensions from being accessible via the auto attendant? I want the users to be able to dial an extension if they know it, but there are some that they should not be able to dial. I would like to keep the extension that needs blocked in the same range of...
  5. chrismec

    SV9100 - 19" 6-Bay version or the 9.5" Plastic 3 bay with 3 bay expansion

    Hi all, we are soon to be getting an SV9100 system which will be installed across several sites. Most sites can fit within 6-bays, but some will require 8 or 9 bays. For the physical hardware there are a couple options, there is a 19" metal 6 bay chassis or you can combine a 9.5" plastic 3 bay...
  6. chrismec

    SV9100 Call Recording (non-voip system)

    Hi all, we are getting a non-voip SV9100 system installed soon and there may be a need in the future to have call recording on a few of the digital extensions. I believe the requirement would be to record all calls on these extensions, both internal and calls on external trunks. I see that NEC...
  7. chrismec

    Hoping for number plan advice for multisite SV9100 (digital/analog)

    Hello, We are in the process of getting an SV9100 system installed at several sites (less than 10), which will be networked together. This will be a digital/analog system only, no VOIP. I am looking to have site 1 extensions in the 1000 range, site 2 in the 2000 range, site 3 in the 3000 range...
  8. chrismec

    LD 20 PRT starts OK then goes downhill

    Hey all, I am needing to get a complete list of TN's but having some issues. This system has been poorly maintained and is on its last legs. Trying various ways to get the info out (LD 20 prt & LD 81) but after a few seconds the terminal data coming in is mostly garbage (corrupted). Have to star...
  9. chrismec

    Option 11 Batteries

    Hello, we have batteries on all our option 11 cabinets and I'm looking to get some information on them. There are four 12V 35AH batteries in a metal case on the floor. Each battery is connected to a harness that plugs into the case. There is test points and a breaker, and the batteries plug...
  10. chrismec

    Meridian auto reset of DTI/PRI alarm

    Hello. Occasionally we have issues with an alarm on DTI/PRI card that requires a reset. Am new to meridian and see there are some possible scripting options. Was going to start setting up a PC script to periodically connect to the switch, check for an alarm and reset the card if there is...
  11. chrismec

    Meridian Option11 Modem access no response after “Ok, You are now transparent to port 1”

    Hello all, been trying to get into our system via modem and am having some issues. I think these issues are on the dialing end as the modem connected to the switch has been dialed into before without issue. Been scrounging around on here and see that I may need to have terminal emulation set to...
  12. chrismec

    Meridian Option11: Get station TN and List available TN's

    Hi all, collateral duty is to take care of an older Meridian system. Grey beard left and goofy cooworkers threw his notes away... Anyway, we have a decent sized Meridian system with several expansion cabinets in offsite locations. Was hoping someone here could share some info on 1.How to look up...