Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations TouchToneTommy on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: rjtripp
  • Content: Threads
  • Order by date
  1. rjtripp

    Call Pilot mailbox line assignment?

    I have installed a call pilot 150 on a norstar mics. The customer has 4 lines that app&ring on 6 phones. They want 2 mailboxes. They want lines 1&2 to ring no answer to mailbox 222 and lines 3&4 to ring no answer to mailbox 224. The only way I was able to make that work is to have lines 1&2...
  2. rjtripp

    Call Pilot Move

    I have been tasked with installing a call pilot system on a Norstar MICS. This is a move or reinstall. I am a little rusty with call pilot. I have only done new installs and have used a phone and also connected with a cross over cable for programming. What would be the best way to connect and...
  3. rjtripp

    Clocking DTA0017 Loop

    I have been tasked with fixing a clocking problem on a CS1000 (opt.11) cabinet. I installed a clock controller daughter board on loop 3 the primary clock, 7 is the secondary. All went well with the install. Clocking is enabled and locked to loop 3. I am not getting any SLIPD on that loop. I...
  4. rjtripp

    Error DTA015 3

    The system is a CS-1000. I am getting a error DTA015 3. I assume this error is coming from loop 3(TMDI PRI). They use this PBX for analog only. Could this effect call processing with DID faxing?
  5. rjtripp

    CS-1000 TMDI Loop Back

    The system is a cs1000 rel.5. I just fixed a major problem with the TMDI cards. They had 3 loops that were no longer connected to the smart jacks (must have happened when they cut over to cisco). They have a fractional T1 that I have looped back to the to the TMDI card. On the telco side the IT...
  6. rjtripp

    Opt.11/CS1000? CPY TYPE

    It has been a while sense I have done some MAC work. I am trying to copy a new 500 set using CPY. I am stumped at the TYPE. I tried 500 and NEW (using a old book) any help? The system SW is Rel. 5
  7. rjtripp

    Opt. 11 Fatal Error

    This system is a Opt. 11 Rel. 5. The customer emailed me pics of the cabinet. I have red alarms on loops 1,2,4,6. Loops 3 and 7 are all that is keeping the system from being out of service. I dialed up the system an as soon as I connected the following error message appeared. TMDI112 1...
  8. rjtripp

    Nortel Tech Support

    Is there any technical support for Nortel pbx at the engineering level? I understand that after Nortel went chapter 11 Avaya took over. Then I just learned Avaya went chapter 11 in the US. So is Nortel pbx on the way of extinction, or is there still a customer base out there?
  9. rjtripp

    Nortel PBX trouble

    I have a trouble (red alarm) on some TMDI cards. Do I have to go to LD 93 and disable the D ch before I try to enable the cards? If so what program (LD) do I find what D ch is on what card?
  10. rjtripp

    Avaya PBX

    Did Avaya file chapter 11?

Part and Inventory Search

Back
Top