Have a small key system installation with Analog call boxes. 2 of them are over the maximum distance allowed. Any recommendations on a ethernet to analog adapter?
So the PGd say it can handle both door box and external paging using o e extendion port dlc
I was able to get external paging working (using first port on dlc blade to Pgd now I need a door box I have jumper set correctly and wires on unit in right place for both but cannot get door box to work...
User are complaining that Voicemails volume going in/out. Was able to duplicate by calling DID leaving VM and message volume went in and out completely. Calls route into 9500 over IP CCIS to 9300 then back to VM where 9500 is located
my routes are 10, 12 , 14
Is this aPad issue if so what are...
On Tuesday desiless phones on 9100 if you have a key ring on second page say a cap key or virtual does it take priority when right gingnor donyou have to scroll when ringing to second page
I habe set up extensions in 46 command and created access code but TDM phomes not receiving all call page. Os there a command to turn on so that other will be proovded to each extension ?
I have 3 phones onsite that when dial out there is a delay from when their voice is heard from distant end. TDM phones. I have 100 other phones onsite that are not experiemcing this problem. Everyone dials out the same PRI , they are in same class of service. After about 5-10 seconds their...
Is there anyway to turn off the light on side car only when user programms one touch button to call another extension. They do not want itnto light up when other user is on their phone
problem getting IP6000 polycom to register
All my ip phones work fine
I have 5 stanard sip station licences
My network 192.168.10.20 for SiP several
Sub 255.255.255.0
Gateway 192.168.10.1
Port 5070
UDP only
Dhcp is off on unit
Extension 3898
Login 3898
Static address
1004 set std sip...
Have a customer need sublines or Virtuals for Departments to flash when there is a voicemail in the box to show on line key
I found 08> 713 > 0
08> 140> 0
still missing something ,, not lighting with message in box
Hi can i download latest version software from NTAC and jump to patest from an old 2.02 . what is the best way to perform this upgrade via PCpro or Stick
AD-8 was replaced IM-16LX on an old 2000. Auto logon works but Message waiting indication not lighting lamps . curious if it the Integrstion string or MWI field ... What should it be set to?
Inmail 9100 I have a custoner with access to PC PRO so they think they can program . someowhere in their creative arts they somehow disabled the logoon feature to access your own mailbox from #and extension number . # on all dial action tables is set to Logon #IXXX and all exts are 3 digit . in...
Hello I have to install for customer a external ringer for an IP extension
On 8500. The device is a ALGO 8180 audio alert . I have installed 3rd Party SIP licence just not sure where to start on 8500. Any step by step commands would be greatly appreciated! Thanks in advance
login failed (activation code certificate T.O. & one-shot password is not assigned)
This is error message I received. Dual CPUs
Customer r does not know if they lost power.
Any assistance would help
I have a 8100 at site A
At site B I have 4 working IP phones
I can call station to station with speech path
However when I do a page all the IP phones get the alert (signaling tone) but speech cannot be heard at site B. Please help.
I am covering an onsite for another technician. The UM4730 is shutting down each day and has to be rebooted to bring it back up. The time is off on voicemail and i remember that the VM server looks at PBX time. They are off by 6 minutes. I need to bring system down to sync time using putty. My...
Went to add station card in unit 2 of 8300 in slot 2. In unit 2 where my VM was working since 2009 i had noticed it stopped. when i realized i was at port capacity i backed station card out but VM failed to reboot even after hard reboot and several saves to both main unit and remote unit.
Call...
trying to add 3rd 8dlca card . Blade configuration not letting me. I think I have a licence issue. Can someone confirm with slots below? trying to add card in slot 3 but only showing me I can add trunks or 4 port SLI card
SLOT 1 CPU
SLOT 2 8 dlca believe it has 2 sli ports on it too.
SLOT 3...
Hi I have a customer with A 9300 and a DSS console or Add on Module. Which do you program and what programs do you use if you want the keys on add/on or DSS to be USER programmable one touch keys ?
I know they need to be a Exxx for DSS
Or ECXX in cd 10 but not sure what to program keys so user...