I have OPT=N for NDC=A0A101B46.
After upgrade from BC9 to MXTSW, on DTS display, you can see DEST 46 in front of dialed No.
Customer complains that this was not the case in BC9.
Is there any way to not show DEST code on display?
Can anyone explain why remote lims can`t see GS (LPU display shows 2020)?
Phisical connections from GJUL4 and GJUG5 to MUX equipment are OK (no alarms on Ascom), all Ascom equipment is in transparent mode, but still no connection!
We have one PRI ISDN (E1) from Telco connected to TLU76 and it`s...
I have a problem with NIU2 flash disk capacity.
Flash is Sandisk 128 MB.
System is BC12, started from INL.
Programming is performed, and when I was doing first DUSYI,
all went wrong.
FISCP:IODEV=SYSDISK1;
FILE SYSTEM CAPACITY DATA
TOTAL DISK SPACE: 122 MBYTES
SUBFS: SYSSUBFS11
KBYTES...
Hi all,
I would like to play info message to caller if there is no ACD agent available for that ACD group(eg. "working hours ..., please call xxxxx").
Is there any way for this to be done, but I don`t want to have live person to answer that call.
I already have WELCOM, QUEUE and REPQUE message...
Can enyone tell me what is the default username and password for accessing local dna server(when first started after instalation).I`ve installed DNA50SP7 application suite and it didn`t ask me for any password. What should I do?
I`ve set up LAN in one company, and as time goes by, that LAN now has about 70 PC`s. There`s no server in system and all PC`s have static IP addresses. Main reason for networking is to share Internet connection. There is one gatewey set by the ISP with IP 192.168.100.1. Is there any way...
I have system reference manual for kx-t336 but i`m not familiar with ways to program it. If someone can tell me where and what i need i would be gratefull.
I`m beginner in this so pleas don`t laugh at me.
I need some simple examples or guidelines for managing a Access 2000 database via WWW.Database is very simple (one table, one report). Thanks a lot.
I have a couple off dbc212 not working on MD110 (they are dead).I have found that the IR1J (shotkey rectifier) is in short circuit but I can`t find the substitution for it.Do anyone have some kind of schematic diagram or have an idea what to do.Many thanks Igor
My company has MD110-bc10 PBX and my job is to program it. PBX came as a donation from Ericsson and first configuration was made by authorised dealer.I have the bc10 manual on CD but have not WinFIOL or some other software for accsesing the PBX.Where can I get this software?