Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations TouchToneTommy on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. phoneboy1one

    SIP Trunking to UM

    we are working on a UM installation and have call prossesing up. when we send a call accross and have the UM send a call back to the CS1000 the DCH shows the incomming digits but the call just drops. CS1000 5.5. Any help would be helpfull. Thanks.
  2. phoneboy1one

    Phone add on module?

    We are are trying do a print on all phones in the sys that have add on modules and I am not having luck in doing this. Is this possible or is there no prt out for this? Any help would be great. Thanks. CS1000 5.5
  3. phoneboy1one

    TM 3.1 ?

    Where are trying to install TM client S/W the installation of the S/W works but when you try and go into the billing module it starts locking up and slowing way down is this normal form TM Client S/W or can we do anything to improve the operation? Any thoughts or help on this would be great!!!
  4. phoneboy1one

    Bars problem please help!

    opt-61c 4.5. having trouble with trunk to trunk transfer CFW to a LD cell phone, this works station to station and it goes, inbound to local calls and it goes inbound and out to one long distance number only witch is 903 it is just out side the metro area all other LD numbers don't get past the...
  5. phoneboy1one

    SYS MON Dip switch settings

    Having trouble with the sys mon on a CS1000 61C 2 Sys monitor cards I can't find info on the dip switch settings for Cab 0 and Cab 1. Does any one know where to find these. Any help would be great. Thanks.
  6. phoneboy1one

    TM web site.

    Having trouble on a new install of TM 3.2 I have installed and built site system. I can access the web page but when I try and login it cant find the server. Any ideas would be great. THANKS.
  7. phoneboy1one

    local and remote carrier TROUBLE?

    Where having an ongoing problem with one way talk path some times reseting the loop corrects the problem but last time we had to change ports on our Adtran is's a 28 port Adtran. This connect to a DS3 thats rides an Sonic ring. So it's like where just working in circles. The carrier cards have...
  8. phoneboy1one

    LD43 Midnight's on an opt11

    If I have ld43 in midnight's will it do an automatic dump to the PCMCIA CF? I will be installing this card as new and I'm going to save all system data then leave it in slot A so will this work? Any help would be great. Thanks.
  9. phoneboy1one

    CP Fax

    Having a problem with a customers CP based Faxing his Inbox keeps filling with the same fax. He is using desktop application. Any clue why this is happening? Please help.
  10. phoneboy1one

    Where to change the default att dn 0 in Applacation Bld?

    We have a customer that we just moved and there DID's Changed to 0XXX so now in Callpilot AppBuilder the MENU Attd Default 0 is conflicting with the lead digit of the ext. Dial by name and dial through is not working it does not go to the ext. We changed the ATT DN to 2 in the PBX. I cant find...
  11. phoneboy1one

    Night service

    The night mode is not ringing the correct ext how do I chg where it rings we want it to go into the gen delivery mail box? Thanks.
  12. phoneboy1one

    Uploading 3904 firmware from a compact flash?

    I have downloaded the firmware from Nortel and I need to find out how to load it from the compact flash drive into the PBX I have a CS1000 61-C with 4.5 on it.

Part and Inventory Search

Back
Top