we are working on a UM installation and have call prossesing up. when we send a call accross and have the UM send a call back to the CS1000 the DCH shows the incomming digits but the call just drops.
CS1000 5.5.
Any help would be helpfull.
Thanks.
We are are trying do a print on all phones in the sys that have add on modules and I am not having luck in doing this. Is this possible or is there no prt out for this?
Any help would be great. Thanks.
CS1000 5.5
Where are trying to install TM client S/W the installation of the S/W works but when you try and go into the billing module it starts locking up and slowing way down is this normal form TM Client S/W or can we do anything to improve the operation?
Any thoughts or help on this would be great!!!
opt-61c 4.5. having trouble with trunk to trunk transfer CFW to a LD cell phone, this works station to station and it goes, inbound to local calls and it goes inbound and out to one long distance number only witch is 903 it is just out side the metro area all other LD numbers don't get past the...
Having trouble with the sys mon on a CS1000 61C 2 Sys monitor cards I can't find info on the dip switch settings for Cab 0 and Cab 1. Does any one know where to find these.
Any help would be great.
Thanks.
Having trouble on a new install of TM 3.2 I have installed and built site system. I can access the web page but when I try and login it cant find the server.
Any ideas would be great. THANKS.
Where having an ongoing problem with one way talk path some times reseting the loop corrects the problem but last time we had to change ports on our Adtran is's a 28 port Adtran. This connect to a DS3 thats rides an Sonic ring. So it's like where just working in circles.
The carrier cards have...
If I have ld43 in midnight's will it do an automatic dump to the PCMCIA CF?
I will be installing this card as new and I'm going to save all system data then leave it in slot A so will this work?
Any help would be great.
Thanks.
Having a problem with a customers CP based Faxing his Inbox keeps filling with the same fax. He is using desktop application. Any clue why this is happening? Please help.
We have a customer that we just moved and there DID's Changed
to 0XXX so now in Callpilot AppBuilder the MENU Attd Default 0 is conflicting with the lead digit of the ext. Dial by name and dial through is not working it does not go to the ext. We changed the ATT DN to 2 in the PBX. I cant find...
I have downloaded the firmware from Nortel and I need to find out how to load it from the compact flash drive into the PBX I have a CS1000 61-C with 4.5 on it.