Hello All
Thanks in advance
I have an NS700 with version 9 on it
All calls are answered by CS1
Option 2 goes to ICD 602 if not answered goes to ICD 601
Option 3 goes to ICD 603 if not answered goes to ICD 601
Option 4 goes to ICD 604 if not answered goes to ICD 601
ICD 601 is fna to 500
If...
Could someone please clarify something for me
I am trying to set up a sip trunk on NS700
From reading the posts on here I am wondering should I have 2 IP addresses.
I believe my trunk is sip peer trunk
Details I was given have 1 IP address for sip server ,no authentation .permit is the static...
Hi
Is there any way to see the slot and port that an extension is connected to using PT programming on a TDA 200
Any info on how to assign an extension to a slot/port using PT programming
I have gone through all the programming numbers and can't see what I need
Thanks in advance
Hello
I have a cordless phone as an extension (slt)of a TDA 30
This phone will show caller id if used directly across the pstn
Will an ext-cid card allow caller id through to the cordless phone when it is an extension?
Thanks in advance
Hello all
I have a tda 30 that loses the customer data after a power down
Is the data held on the SD card or on the main board
I presume it is on the main board and the battery is dead
If so can the battery be replaced ?
Thanks In Advance
Hello all
Any thoughts about the NS700 and using mobile phones as extensions
Do mobile work well as extensions?
Will the mobile wake up when a call is incoming
I have tried mobiles on a 3cx platform and the push notification does not work reliably.
If the mobile phone is asleep the caller gets...
Hi All
Hope someone can point me in the right direction
Situation is this
M2250 is faulty
System is in night
Set up new extension and pointed NIT1 in to this new extension
There are 3 POTS trunks on the system terminated on XFCOT card
All 3 three trunks will call in on the new extension
ACOD is...
Hello All
Your advice requested with the following please
Incoming calls answered by custom menu inviting callers to dial 2 for 202,3 for 203 and 4 for 204
If any of the above extensions are busy or no answer the call goes to 201.
If 201 is busy or no answer the call goes to the general delivery...
Hello All
I have a problem I wonder if you can help
I need to use DXDP on a tda 30 ,
On the slave phone T7633 the display comes up ,I can ring out to another extension from it and I can ring in to the slave.The master phone is a T7633 as well
However I have no dial tone on the handset or using...
Hi All
Having difficulty connecting to a TES 824
ROM ver Y911AG070731 BX using usb and Ver 3 of console
Error Message is "Cannot connect with the PBX of this firmware version or Model Type (01213507H)"
Any help greatly appreciated
Thanks in advance
Hi All
Does the BRA ISDN have to be set at P-P or is it just required that the TDA matches the setting of the ISDN line
I have no dial tone for short periods on the 3 basic rates
I see a post from OBT with the settings as Permanent Permanent P-P and Fix 0
If the isdn circuits are P-MP must they...
Hello All
I have an issue with a KX TA 624 with 2 lines and 8 extensions
Both lines are programmed to call on extension 201 under 414 DIL Jack 01
Extension 201 has FWD B/NA active to extension 206
Occasionally other extensions in the premises ring on incoming calls which the customer does'nt...
Hi All
Quick question
Is caller id built in on the TES824 for the first co 3 lines?
I see there is a caller id card 82493,is this for the extra co lines ?
Thanks in Advance
Hello All
Can anyone tell me if the KX TA 308 is expandable.
There is a card KX TA 30874 which looks as if it would provide 8 analogue extensions but I read on some site that the KX TA was not expandable but the only manual I can find seems to refer to an American Version.I am in Ireland...
Hello All
KX-TD816 with TVP 50
Been reading posts on systems being hacked to fraudulently make calls
By default transfer to outside party is disabled and call forward to outside party is disabled
Is this enough ?
Should I change the cos of the VM ports to cos 8
Thanks in advance
Hi All
I have an 816 (software P411K00306H) with a TVP 50
I have custom menus set up on the TVP and calls are transfered from the VPS to single extensions and to groups with 2 or more extensions.
If a call from the VPS goes to a single ext say 205 and is not answered the VPS takes the call back...
Hi All
Second problem I have relates to message waiting lamp for GDM
system is TD 816 ver 5 with TVP50 VPS
Extn 215 is the operator 1
In the VPS programming under operator parameters operators extension is shown as 0 wont let me enter 215
Operator mailbox is 998
Its possible to leave messages...
Hi
Can anyone help with this
Very frequently I cant get dial tone on these isdn lines ,They are CO 1,2,3,4 and when u press the line keys in turn dial tone will be on the line ., can do this 3/4 time in a row and everything works fine. the next time u try to sieze a line by pressing any of the...