  1. chrislxx

    OPT 11 will not boot

    Hi i just moved a working option 11 from to another (shipped it) and now it will not boot up. is there any way to recover form this? I have posted what i see below. The system has the PCMCIA cards with a backup, however we do not have the keys. thank you in advance for any help. Chris...
  2. chrislxx

    No name display calling Asterisk to Nortel opt 11

    Hi I have connected a Asterisk (11) to a Nortel Opt 11 Succession 3. The connect is TIE using QSIG. Calls are processing however there is no name display calling from the asterisk to the Nortel. Any help is greatly appreciated. Below is my Nortel configuration. Thank you in advance for any...
  3. chrislxx

    OPT 11 to asterisk & name display

    Hi A PRI is connected between a OPT 11 Succession 3 and a Asterisk. Calls pass OK between the 2 switches, however the name display does not pass through. I have used IFC = ISGF. Attached below is my configuration. Please tell me if i have the Nortel settings correct. Also i need the OPT11...
  4. chrislxx

    NTDK70BBE5 help

    We just had a failure of a power supply and none of my usual sources have this one. What is the difference between a NTDK70BBE5 and a NTDK70BB as I seem to be able to find those? Or is there another part number that will work? Or if anyone knows where I can get one in Salt Lake (the switch is...
  5. chrislxx

    Can not ser SIGO to ESN5 on a opt 61 Succession 3.0

    Hi I am building a new TIE route and need to set the SIGO for the ROUT in LD 16 to ESN5. The route defaults to STD. In LD 17 is states to use ESN5 I need to set VSIG to YES but I do not get prompted for that option. The system is Succession 3.0 I am trying to use ESN5 to have message lights...
  6. chrislxx

    foward the attendant during lunch

    Hi I am being asked if there is a way to forward the attendant to another office during lunch. The offices that need to be forwarded are OPT 11 v25 and OPT 11 succession 3. These would be forwarded to an office with an OPT 61. They are connected with PTI tie lines. Any suggestions would be...
  7. chrislxx

    Call Fowarding to Enternal DN not working from inside calls

    Hi I am having a problem setting up Call Forward to External DN. I seem to be having the opposite problem that I have found by searching the subject. Most can’t get it to forward from the outside world but I can. When a call comes in from the outside (PRI DID trunk) world it forwards properly...
  8. chrislxx

    CAUSE :INVALID IE CONTENTS error on PRI

    Hi Thank you in advance for any help I am installing a new PRI with ATT I have a opt 11 rls 25 I have a NTAK93 so i can only NATL is not an option ATT is a DMS 100 set for 5ESS I can receive calls but when I call out I get ******************************************************* DCH 11 IMSG REL...
  9. chrislxx

    Call Pilot 02.01.07 with bad hard drive

    Hi I have a Call Pilot 02.01.07 It is running Windows NT server with what appears to be 2 SCSI drives mirrored. One of the drives has failed, the SCSI controller dose not even recognize that it is there. Can I simply replace the drive with similar drive? The Drive is a Maxtor 8B036L0021611. Is...
  10. chrislxx

    Revert DN accross PRI tieline not working

    Hi I have a problem with the “REVERT DN” on my meridian mail r 10 when it is set to the DN (the console LDN) of a OPT 11 across a PRI tie line. MM is on a option 11 r 24 After MM answers the call and “0” is pressed MM responds that “your call can not be completed at this time please try again...
  11. chrislxx

    outlook shows messages read when they are not

    We have a few users here that have more than one computer with their outlook up at the same time. Periodically one of the computers will show all of the messages as read, and the others will not. The massages have not been opened. Any help would be greatly appreciated. Chris
  12. chrislxx

    No message indicator from remote Meridian mail

    Hi I do not get an indicator of new mail on a option 11c with the meridian mail hosted on a option 61. They are connected with a PRI tie line. I just added this as we added a new location and I has a spare option 11c. I have another option 11c just like this one that the indicator works from...
  13. chrislxx

    help with opt 11 adding second PRI card.

    Hi I am adding the second PRI card the first is used with a tie line and it is in slot 1. (Below is the CFN) The new card will be in the second slot (card 2) Is the card 2 loop 2? When I try to add DCH 12 for the new PRI TYPE CFN ADAN NEW DCH 12 CTYP MSDL CDNO 2 SCH3722 CDNO Have I...
  14. chrislxx

    new tie lines cant tandem call in one direction

    I know I am forgetting something here but this is my problem. I have TIE Trunks coming in from different cities; I use CDP to point to a route. There originally 3 satellite cities they can all call each other. I added the 4th last week, it can call everyone, but when others try to call them...
  15. chrislxx

    Tie line opt61 rls 24 digital em b ch siginiling nt5d12

    Hi I am trying to create a tieline that is not PRI but T1 e&m (a-b-bit ) signiling. I have been trying to configure a nt5d12 with no luck. any advice? Chris