I need to switch out a UPS that has three systems on it....a NORSTAR , OPT 61 and a Definity....I got the Norstar and the OPT 61.............HOW do I down a difinity and then bring it back up and stat it to make sure all is good???????
Just a squirrel trying to get a nut...
www.tmaxx.biz
How do I change time on a meridian and then check to make sure it will observe Daylight Savings Time next time around?
Just a squirrel trying to get a nut...
www.tmaxx.biz
I need to set up a SMALL call center consisting of three phones in an ACD group......Any one got a cheat sheet??????I havent done this in YEARS!!!!!!
Just a squirrel trying to get a nut...
www.tmaxx.biz
I need to set up a SMALL call center on a Norstar with a Call Pilot.....Can anyone point me to a good cheat sheet in order to make this go relatively easy??????
Just a squirrel trying to get a nut...
www.tmaxx.biz
I am adding a new group of 24 and I am trying to copy the programming from the first group...This is what I have done so far.....
ld 20
prt
tnb
and found 26 24 to be teh last tn in that group
then to ld 14
req new 24
type did
tn this is where I am not sure what to put in ......this loop 27...
Does anyone know where I can obtain an copy of the older release of 22.46 for an option 61 with older CMDU's with floppy drives ONLY........
Just a squirrel trying to get a nut...
www.telemaxx.biz
How do I get the system ID or serial number for an opt 61....I tried in ld 22 but not sure if I did this correctly or not....Thanks in advance.....Robert
I need to replace a CMDU in an opt 81 switch I believe it is a simple process and I would like to know what the correct process is. The old CMDU was sent out and refurbed, I now need to re-instal it, the switch is in maintenance mode already and running off of teh other CMDU. Thanks in...
I have an existing 2616 (ext xxxx) I need to replace with a 2008 and then move the old 2616 to a new person with a new extension....any help would be appreciated.
I need to add speed dial to a cics. When using f*1 the number takes , but when I push the associated button it acts like it is dialing the number but it is not making the call?
Option 11.....I am having an issue with 500 analog sets and the message waiting light not working....The light works on all the digital 2616's in the system just not on the 500 sets....any thoughts????
Thanks in advance,
Robert
I am getting this code when trying to change a name.....I try to out teh old and it gives me the code....sch2119 when I put the dn in.....it is the secondary dn not the primary..ie: primary dn on key 0=502 secondary on key 1=3502
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.