I am using an old option 11 cabinet to back up priority phones for an option 61 we are taking down for maintenance issues. Card and cabinet is built and was working recently at another site. I cannot establish connection with PRI. DCH has green light, clocking is red and I get a intermittent red...
We have over 1100 ip phones at a customer working on srg's off a cs1000 5.5. There 15 sites that have srg's and a couple that are strictly bcm's. When the network drops or has any kind of trouble there are always 5 to 20 sets at different locations that do not recover from from local mode...
i support a cs1000 for a school system. this is a 5.5 level. the main switch is at the board office and there are several school locations. there are several 1.5 srg's (200/400), and there are 5 or 6 bcm 200/400 and one new bcm 450.
my problem is the school administrator noticed that there is...
We are doing a 5.5 upgrade on a cs1000. there are 8 locations throughout the system. there are 4 locations with 4.0 bcm 200s with a 1.5 srg that work register fine. there are also 4 locations with 3.7 bcm 200s with a 1.0 srg that do not register and/or act really flakey.
i think it is a...
i am wanting to upgrade a 3.7 bcm platform with a 1.0 srg to a 4.02.3 bcm with srg. i have been given keycodes for a 1.0 srg. i have been told that the 4.0 does not need 1.5 srg keycodes to work. my ip phones will not come up. message on phone says server: no ports left.
does a 4.0 need a...
3.7 bcm 1.0 srg hardrive failed when making an upgrade for cs1000 to 5.5. only available srg was a 4.0. our tech support gave us an upgrade nortel keycodes for the srg making it a 4.0 bcm 1.0 srg. when trying to register a 1140 phone we get a 'no server ports left'. i can ping the srg and...
i have been upgrading option 11 switches to 5.0 for a municipal government. all had been going well until last night when trying to change time. someone had changed the second level password and no one knows what it is. how can i change it?
i have a 3.0 cs 1000 in a option 11 cabinet. they have license for 48 phones with 43 registered. occasionally at night, these phones will disconnect but all but maybe 6 or 7 will reregister with those 6 or 7 searching for server. these phones can be unplugged and register immediately the next...
i desparately need any tips on starting up a sig server as a failsafe. when i go through startup cd disc and after copying files, it gives me an error message about bootp and a configuration error. i tried building as a follower.
i just shut it down until i get some info.
trying to add a kem to i1140 phone. this is a cs 1000s. no light comes on with kem but has a reading of i00v138 and just below v138 appears on the kem. i changed all of the class of service settings and made each key on the unit a BSF. example: key 32 bsf 61 0.
any info much appreciated.
i have a customer we just updated to 4.5 and they say they used to hear two short rings for station to station calls within the system and one longer ring for incoming calls. i am going to make some changes in cls tommorow with a DRDA but any info would be appreciated.
i will be installing a CS1000s next week for the first time. This will connect a banking network. Does anyone have any quick insights, tips, lookfors or lookoutfors.
thanks