Hi, I have several 4610SW IP phones sets that I want to change to SIP for using them with asterisk PBX, Please, Does anyone have the 4610SW SIP firmware and the 46xxsettings.txt file or where can I download those files?
I saw this post: https://www.tek-tips.com/threads/avaya-4610sw-help.1543241/...
Trunks have NCOS 0 (just for internal calls) but CLS UNR:
Asterisk-11c Interconection trunk:
DES FREEPBX
TN 002 01
TYPE DID
CUST 0
TRK DTI2
SICA 2
PDCA 1
PCML A
NCOS 0
RTMB 1 1
NITE
AST NO
IAPG 0
CLS UNR MFC CNA WTA LPR APN THFD BARD
P10
MFLI 0
MFPD NO
TKID
DTCR NO
DATE 7 FEB 2025...
Hi, I've got a button for adding fields (select option value and Input) to a html-JavaScript table, When I select an element from the select option value (idmedico) I use onchange option in the select for going to a JavaScript function for fetching the name for the idmedico and then populate...
Hi, I've got a Meridian 11c rls 25.30, I want to interconnect the 11c with an asterisk using a NTAK79BA PRI card (in 11c) and A108 Sangoma card (in Issabel Asterisk), please Could somebody help me with 11c parameters: ld 17 - D channel, ld 16 Rout, ld 15 NET, ld 14 TIE port, ld 73. And If...
Thanks for your answer, I did the following and It works:
$query = "SELECT * FROM tbl_order_id,customers WHERE ";
$query .= 'tbl_order_id.customer_id=customers.customer_id AND ';
if($_POST["is_date_search"] == "yes")
{
if($_POST["customer_name"] != "")
{
$query .= '...
Hi, I've got two mysql tables "tbl_order_id" and "customers", the mysql tables have in common the field "customer_id", I want to join tables using customer_id for showing customer_name field in datatable (customer_name is in table customers)
This is my tbl_order_id table:
This is my...
Hi, I've got a customer with a CS1000 rls 6 co-resident (CPPM), They have two DTI2Mb cards (E1), They have Ip telephones 1140e,2004 etc.(unistim), digital and analog traditional phones. But I've got the following problem: When The E1's card present errors (For failure in the carrier) the Ip...
Hi, I have to change TTY port to BITL:7 and PARY:EVEN, because TTY 6 is configured as ACD for sending ACD data to capture it in Visual Basic 2010, If I use 9600,N,8,1 in TTY the ACD data arrive corrupted to visual basic (If I use procomm to capture data, the data arrive ok, but in Hyperterminal...
Thanks bignose21, I disabled and tried to change serial port on MGC but I didn't work, it skips BITL and PARY parameters, I worked deleting and creating again TTY.
The serial port (COM)I want to change Parity (PARY) to:EVEN and data bit lenght (BITL) to: 7 is in MGC 0 0 this are the parameters that has:
ADAN TTY 6
CTYP MGC
IPMG 0 0
DNUM 6
PORT 1
DES callcenter
BPS 9600
BITL 8
STOP 1
PARY NONE
FLOW NO
USER ACD
CUST...
Hi, I've got a CS1000 rls 6 co-resident I want to change a TTY (ADAN) Parity and data bit lenght, but manual says (LD 17):
Note: This prompt is blocked for co-resident Call Server applications (Call Server and Signaling Server applications co-located on a CP PM server). Serial port configuration...
Now because I erase the DS30 using "AT-X" command, I'm trying to upload the BIN file to the DS30 module, for doing that I set up the Ip Office Manager (version 10.1(67)) for TFTP transfer bin file to DS30 module, The TFTP Log shows the DS30 bin file request, the following image shows TFTP log...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.