I need to create a tandem operation.
What I am trying to achieve is having calls that come in on a pri line automaticly grab a trunk from a regular co line.
and if a call comes in on a regular co line routes the call to the T1\E1
Can this be done.
I can not find any examples of tandem...
Currently I have Dcs working between two Definity's both are R9.5
exension dialing is working between the two.
i would like to set up a central attendant, will the BLF field work at principal attendant?
Also on switch 2 how do I point to the attendent on switch one.
DCS trunk group is set to...
I when I checked the error log this morning I had tone clock error I am using a 2182 tone clock, I do not have a external clock reference, incoming lines are pots. the TDM- Clock error is 1281 which has to do with time slips
Here is the ds1 config on Switch1
Location: 01A15...
I did create a crossover arrangement as you recommended.
the errors that I am now getting are sync 1793
and UDS1-BD 3109 and 3073
Do I need to have the sync configured? I do have it configured on both systems.
Also it it possiable to do this without the ICSU's
I have two definity's both are r9.5
Each has a tn464f and a ICSU attached. The problem seems to be the signaling group. I have followed the examples in the d81 network conectivity manual but the D channel does not seem to want to come up.
Am I missing something?
I would like to know the best way to setup night service.
I have purchased a BOGEN NR100 which will produce a ring tone over our paging system.
What we would like is when in night mode or using DID number, will ring all over the plant.
We would like a to be able to go to any station dial...