Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Wanet Telecoms Ltd on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. artikar

    Aastra Dect problem with disconnect and no ring signal when calling a dect,

    Hello. I removed all programming on 131 with. cxake pelpe gedie nanse:numtype=ex,numse=131; nansi:numtyp=ed,numse=131; nanse:numtyp=ed And program everything back , start with nansi:numtyp=ex,numse=131, Now is everything ok, possible there was something with the number 131, i dont now but...
  2. artikar

    Aastra Dect problem with disconnect and no ring signal when calling a dect,

    Here is the data, i have use the 131 with pelpi to 131 for 2 days now, and the customer has no problem .. I belive there is someting with the number 131. CORDLESS EXTENSION AUTHENTICATION KEY DATA DIR AUTKEY IPEI...
  3. artikar

    Mx-One, Problem with A-number when transfer a call,

    Some more info, When a call from my cell phone to the number ex 123, and the call is transfer to number 124. 123 become the A-number on 124.( not my cellphone number ) If i used pelpi on 123, list 1 cho 1 124. And call from my cell phone to 123, my cell phone number become the A-number on...
  4. artikar

    Aastra Dect problem with disconnect and no ring signal when calling a dect,

    Hei. I have a problem with Dect and when i used number 131, if i change to another number like 191 everyting is OK The problem is that the Dect phone does not always ring when i call 131, and if it ring and the phone is answered , the call been disconnect. When i call the 131 i see i...
  5. artikar

    MEW on Dect TSW SP04

    Thanks for the tip doctor,everything OK Sorry that i forgot to thank you earlier. Regards Per-A
  6. artikar

    Problem with Mamager provision,

    Thanks i restart eri_mp and everthing is ok. Thanks again Per-A
  7. artikar

    Problem with Mamager provision,

    Thanks I have tried with restart -unit ERI_OM -lim 1 MDSH> restart -unit ERI_OM -lim 1 ERI_OM doesn't exist in system Here is what i got fraom Mx-One. Per-A
  8. artikar

    Problem with Mamager provision,

    Hello I have a problem with Manager Provision, cant connect to the Mx-one. I open my explorer/firefox and type in the IP adress to the Mx-one, and get the page to write user name and password, but cant get any connection to the Mx.one This have been OK, but no i cant connect th Mx-One. Any...
  9. artikar

    Mx-One, Problem with A-number when transfer a call,

    Hello I have a customer with a Mx-one, Version: 4.1 SP4 Hotfix1 build4 When customer call the operator/extension, and he operator/extension transfer the call to another telephone intern or extern, the telephone number to the operator/extension come in the display on the phone. Not the...
  10. artikar

    MEW on Dect TSW SP04

    ...use of personal Voice Mail. I Have problem that the MEW lamp/Icon is activatet without reason. The only way to remove the lamp is with dial #91#* form the Dect with the MEW activated. Cant find the reason taht the MEW lamp is activatet,i have tried to remove the number and the dect, and...
  11. artikar

    Aastra BP250 Dialtone is delayed, recived dialtone 2,5 sek after lifttoff handset

    When i change the CPU D5,and start up the BP250, there was a delay. I have check the Aastra Compatibility Overview, and the CPU D5 have R1C but the the recommended is min R1M. I wil trie a CPU D5 with min R1M
  12. artikar

    Aastra BP250 Dialtone is delayed, recived dialtone 2,5 sek after lifttoff handset

    I have check the warning log nothing there. I move all 5 eproms from the CPU 5 bord to this new one.
  13. artikar

    Aastra BP250 Dialtone is delayed, recived dialtone 2,5 sek after lifttoff handset

    The system is small 15 digital , 6 analog and 10 Dect with 3 base station, and low traffic. I have check configuration but can not find any error, have also tried to change the MFU bord , still delay..
  14. artikar

    Aastra BP250 problem with import backup file from PC to BMS

    Thanks etompau. Your tip help me today, i set the security in explorer to minimum and the import was OK. Thanks . Regards Per-A
  15. artikar

    Aastra BP250 Dialtone is delayed, recived dialtone 2,5 sek after lifttoff handset

    Hello I had a problem with cpu in a Aastra BP250, changes the CPU D5 and send inn the backupe file with BMS. The BP is working allmost OK, Digital, analog and Dect phones are ok, but there is a problem with delay in everyting. When i push the speaker putton, lift of the handsett, i recive the...
  16. artikar

    Hello I had a problem with cpu in

    Hello I had a problem with cpu in a Aastra BP250, changes the CPU D5 and send inn the backupe file with BMS. The BP is working allmost OK, Digital, analog and Dect phones are ok, but there is a problem with delay in everyting. When i push the speaker putton, lift of the handsett, i recive the...
  17. artikar

    Aastra BP250 problem with import backup file from PC to BMS

    I have problem with a BP 250, PBX stop working very often, after restart everything is OK. I belive there is something wrong with the CPU D5. I have taken a Backup and try to import the backup file XXXXXX.BMS into BMS, and into a new CPU D5. I got this error in BMS when i tried to import to...
  18. artikar

    Prblems with IP Telphone DBC 425

    I have i MD 110 with 10 old IP telephone and want to connect 10 new IP Phone, i expand with one ELU 32 boards. I have a MD110 with SW BC12 SP12 and i want to connect 10 IP Phone DBC 425 ( the new IP phone Ericsson ). The problem is that the phone is deliveret with SW R2b and R2C. The phone...
  19. artikar

    IP Telephone som questions problem

    Hi I have a customer that use IP Telephones Dailog 3413, In the alarmlogg i get tho messages that i dont like. 355 IP EXTENSION BOARD, UNACCEPTABLE QUALITY OF SERVICE DATE TIME ALP NOIF UNIT EQU BRDID INF1 03JUN03 13:06:40 2 9 IPLP 001-0-32-00 114 0...
  20. artikar

    Ericson BP 50 problem with changes langwitch

    I have got the answer, too ho is inntresenting. The language changes with proms, there are 3 kind of proms 1 for the display 1 for the functions the customer whis too by 1 for the speaker promts inn the woice Per-Arne

Part and Inventory Search

Back
Top