Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations TouchToneTommy on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. AirCon

    Configure Win2000 server as a domain

    Hi nsanto17, Thanks for your reply. First of all (as I've mentioned) It's been so long for me since the last time I installed server (1996 with NT4 server). Now I'm kind of confused with Win2000 server (I feel like a newbie :-D ). So forgive me if I have many questions. Also since I'm not on...
  2. AirCon

    Configure Win2000 server as a domain

    I have read the FAQ's for setting up DNS. One thing I've noticed from the FAQ is "Don't set IP 127.0.0.1 as DNS server". I think this is a problem, because the server using this IP for the DNS. I've tried to configure this IP (from TCP-IP network protocol), but the server automatically reset...
  3. AirCon

    Configure Win2000 server as a domain

    Hi all, This is my first question here, please bear with me :-) A client of mine ask me to help them to configure win2000 server as a domain. And it's been so long since the last time I installed a server. So I'm kind of confuse here and really need help on this Currently they have a server...
  4. AirCon

    resizable class not working with subclass

    I'm Not sure what is happening. I need more info for this. Is the "Newtextbox" added to the poperties of resizable class in solution.vcx or added to resizable class in your form ? If it was added to the class in solution.vcx, check the resizable class in your form. Does the properties also...
  5. AirCon

    Common Dialog Position

    Oopss! :-D What I mean is: If you trying to get the handle prior to the call -- AirCon --
  6. AirCon

    Common Dialog Position

    Ok, I think you haven't get it why the key to this tehcnique is TIMER. Why we have to use it? Because that window is not exist yet! It is created inside the function/API that we are calling. That's why we have to use the TIMER in order to get the handle to that window. This timer act like...
  7. AirCon

    Common Dialog Position

    Mike, I have tried this technique (timer) long ago. What happened is when VFP call the CommonDialog the VFP app will stop and wait for the Dialog not even the timer will run! You can try this yourself: Add nCounter property to the form. Add the timer object with interval 500 (half msec) then...
  8. AirCon

    Common Dialog Position

    Andreas (& Mike) You can set MessageBox position, caption, etc.. with VFP only (using timer, ugly solution anyway), however you can't do the same thing for CommonDialog, because it is not the same Instance/Thread as VFP There is a DLL wrapper (in UT) with position for CommonDialog but no...
  9. AirCon

    Syscall problem

    Ahh.. no wonder. I'm sorry, can't help you in this case. I don't have any experience with Linux. Anyone ? -- AirCon --
  10. AirCon

    Report and empty lines

    Tom, That's the first thing that came to my mind. Well, how about make a UDF and check for EOF() ? -- AirCon --
  11. AirCon

    Report and empty lines

    Hi Tom, How about append blank records (as many as you need) to fill the page ? -- AirCon --
  12. AirCon

    Syscall problem

    Hi keratox, I'm not sure what are you trying to achieve with that code. But if I look from it, I can't see what's wrong. Is that only a small part of your code? Try to trace (from the debugger) step by step. -- AirCon --
  13. AirCon

    Problem - running app from project works, but compiled exe flashes by

    Hi Zeaglefeather, Don't use the menu as your main. Create a program (PRG) as a main and set it as your "main project". In the main program you can add this code: DO MENU MyMenu.mpr READ EVENTS Don't forget to issue CLEAR EVENTS (in your quit menu) to quit the application Hope it works --...
  14. AirCon

    resizable class not working with subclass

    You missed one more property which is ResizeList. Also you have to be carefull when you add the name of your class into that list, It's case sensitive. Regards -- AirCon --
  15. AirCon

    Windows Explorer - Browse

    Yes it works for browsing local directories. I tried with C, D then navigate (double click) thru subfolder, it stays on the same form! Perhaps you could ask about this setting in W2K forum Hope you can work it out -- AirCon --
  16. AirCon

    Windows Explorer - Browse

    ITFlash, As Baltman said, the problem is from IE options settings. Because in my machine (IE 5.5) it doesn't open/launch a new window when I open/double click a new folder. -- AirCon --
  17. AirCon

    Faster DELTREE command ?

    Windows use a smartdrive mechanism. For DOS you have to load SmartDrv.exe yourself. Edit autoexec.bat, put this on the last line: Smartdrv 8192 8192 It should work much faster :-) Notes: it is better to flush the cached before reboot/turn off the computer, by typing "smartdrv /c" at DOS...
  18. AirCon

    Windows Explorer - Browse

    itflash, I think this might be what you are looking for. Run the Solution example. Solution -> Foundation Classes -> Create a Visual Foxpro Web browser. -- AirCon --
  19. AirCon

    Obscure C/R disables Click event !!!!

    Put this command before/after the blank lines: This.Parent.Click() -- AirCon --
  20. AirCon

    Modifying numerous records - year part of the date

    Dabase, Just to add to mm0000 suggestion, try this: REPLACE ALL dbirth ; WITH gomonth(dbirth, 1200) ; FOR (Year(dbirth) < 1000) -- AirCon --