Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations bkrike on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by ygelman

  1. ygelman

    Need call recording

    Hello guys. I'm using Nortel Norstar system ver. 6 to which I have monitoring and call recording capabilities. I already spoke with NICE, VoiceGate to look for the solution which will connect to the PBX and allow me: 1. Recording of conversations at specific phone(s)(read DID). 2. Will allow...
  2. ygelman

    New T1 line

    100% sure. The only thing I still not clear on is when I set the second card to be of T1 type. Does system automatically assign it to pool B or I have to do this? If it should be done manually - how it is done.... I didn't find any answers in Norstar documentation. Thanks, Yuri.
  3. ygelman

    New T1 line

    We have following setup: Initally there was PRI line that now serves all the business users. Now we want to connect the secondary dedicated T1 line to serve the long distance calls. Given this setup what is most optimal approach to connect and use dedicated T1 line. Thanks for help, Yuri.
  4. ygelman

    New T1 line

    Marv01, Thanks for teh inof so far. More details are as follow: the 1st line I have in IS a PRI ---> I am tryng to creat two seperate pools now (one for thr PIR [local calls] one for the T1 [LD calls]) ----> My problem is that I cannot assign pool B to teh T1 line (is...
  5. ygelman

    Analog modules.

    Commsguy, lets not discuss my experience here.
  6. ygelman

    New T1 line

    Absolutely sure. I just went to Maintenance section and disconnected the KSU(2). Then I went to Hardware and changed the setting for 2 card to be T1. And then I connected the KSU(2) again. Now I will have to assign the T1 to pool B. How do I do this? Thanks, Yuri.
  7. ygelman

    New T1 line

    It is Nortel Norstar. The line that I'm trying to connect is the dedicated T1. When I go to Hardware.CardsOnKSU section the card that line is connected to is showing as PRI. When I try to change the setting to T1 it gives me "Disable card" message. What should I do? Thanks, Yuri
  8. ygelman

    New T1 line

    Hello forum. I'm trying to add secondary T1 line to the system. What is the best way to add it. Thanks, Yuri
  9. ygelman

    Analog modules.

    So let me just put all the things together. 1. I have to purchase 12x0 and connect it to the system. 2. Then I can connect all the analog lines to it. 3. Then I have to set up Pool A to contain PRI_1 4. Then I have to set up Pool B to contain PRI_2 5. Then I have to set up Pool C to contain...
  10. ygelman

    Analog modules.

    Do you have any documentation about that module by any chanse? Thanks a lot for your help. Yuri.
  11. ygelman

    Analog modules.

    0x12 or 12x0?
  12. ygelman

    Analog modules.

    Hello forum. Recently we had some troubles with our T1 provider which were caused by the Pacific Bell malfunctioning wires. In order to provide business contigiency - we thought to enable fail over the plain analog lines which we are using in the business. As I understood from documentation...
  13. ygelman

    Querying LDAP returns empty recordset.

    Hello forum. Something strange happens with my web server. I'm trying to use ADSI to extract user information from LDAP. Web server that I'm using is - of course IIS installed on Win2k. As well I installed the ADSI from the disk. And promoted the machine to be AD server( after thet I verified...
  14. ygelman

    dcpromo fails because of DNS

    And here is the new one: The Directory Service failed to replicate off changes made locally. "The replication operation failed because of a schema mismatch between the servers involved. "
  15. ygelman

    dcpromo fails because of DNS

    Hello guys. Thanks for the help. Here is what I did - I've added the own IP address to tcp/ip settings of the DNS server which is the PDC as well and when tried to run the dcpromo I've got following error: *********************************************************** The Directory Service failed...

Part and Inventory Search