Thanks allecmac for your response. I looks like I have to get Pkg 175 in site B. Do you know of other documentation other then 555-7101-302 to implement this feature. Thanks
I will be implementing NMS with CallPilot 201i for a customer site. My question is after reading documentation and engineering guide, I believe that if I have site A that has a CallPilot server (prime site) and site B (satellite site) with sip trk with D channel connected using CDP, that would...
Thanks 9210. I am planing to use one at the customer. After tacking to a few teck’s yesterday, I seem that the Loadware MGCCAD46 is older. So I will replace it with MGCCAH17 and I am told that it should fix the problem. Thanks again.
I think after looking through all Nortel bulletin, I found the MGCCAH17 that I don’t have loaded. That may fix my problem. I would still appreciate your comment if you had this problem. I still have to try it a customer site.
Has anyone upgraded Opt 11 cabinet with NTAK11 to Rls 5.0 using CPPM C/S & S/S
with MGC’S NTDW61BAE5 96 DSP (DB96 in position 1) tn 11,12,13, on both. My problem is that I have 2 cabinets NTAK11 at the customer site with PRI in slot 6 in the 1st cabinet. At this time we are not
connected to...
Thanks guys. I went and changed the password length and some reason it let me program 3 digit mailbox. Never cease to amaze me. Thanks you guys for your responce.
I have a system that is migrating from Meridian Mail to CallPilot. The Merdian Mail
has 3 digit lengths MailBox. I have migrated the Mailbox to CallPilot but when I go to greater a new MailBox in CallPilot with 3 digits, it is giving me a error that the mailbox
length has to be 4 to 18 digit. I...
Can anyone tell me if it’s possible to do a traffic study on 2 PRI spans. In LD 2 should I set a report for trunks. Would that capture PRI information. THANKS
Thanks dlesap. I have window to restart the Sig Server next week so I will give it a go. One more point that I,m not clear on. Does the Sip Domain Name have to be the SAME in all 3 Sig Server and the Sip Gateway Endpoint Name is the name of the Sig Server at that specific site. Thanks again.
Thanks dlesap. CS Virtual routes are good. They are working fine between the Alternate and Failsafe using 4 digit CDP.
I did some more reading after you mentioned Dynamic registration and found it in (IP Peer Networking) NTP's Should I be following the (Enabling and Configuring the NRS server in...
I am implementing IP Peer between 3 sites with SIP. I have 2 site configured with Virtual TRK &D channel. I have these sites working with CDP without NRS implemented. They are configured as Alternate and Failsafe. I will be adding the main site witch will be the Primary and the co-resident NRS...
Thanks John. From you suggestions, being an 81C to you think that moving 1 card at a time ( 24-0-1) is possible instead of moving the loop (24-0). Being supper loops I am a little confused with the (STUN) prompt in LD 25 where it says, The source card must NOT
Be on a supper loop; the...
Can anyone tell me if I can move a supperloop (LD 25)? to a new supperloop. Example: Moving supperloop 24 to make room for new DDP card PRI 24 & 25. Want to move supperloop 24 to an new supperloop 20-1. Already have 20-0, by reusing the IPE shelf from loop 24. Just have to move the ENET cable...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.