Dear everyone,
i have 500 sets of M3904 digial phone to be add into system of Option-11c , All phone class and key assignment are same, everybady who can tell me how to bulid the procomm script to make input easily?
Thank you very much.
Steven
Dear all,
my system is OPT11c , and software version is Rls 4.50W with voicemail to Rls 13.14.2 , when dial internal vm number(4323),
error code occupied [ERR648 VITN: 00000CCF] ; system not install the ITG card. i already check that's fault of R4.50W , everyone have any patch to solve this...
Hello,
you can set HOML to NO on ACD-DN , if HOML not show , you can turn on AID-yes under SCB by LD23. at M3904 telephone option select on-hook patch, set headset selected , you can login agent without lifting the handset. (phone setting refer to M3904 user guide P1002625)
good luck.
Steven
john,
i has been try to connected the pc console with power's tn under the switch system CS1000E,but when over length around 120 meter , press loop key hear the noise. did you known it is CS1000E problem?
thank's
steven.
hi john,
thank's for your help.
for my case: pc consle with my siwth(cs1000E)around 120Meter , i was try to connect with powee's TN ( 3rd tn , 4th&5th TN) but can't work.can you detail to me how to connect with pc console?
my connection as below.
=========================================
DB-25...
Hi,
The midnight routtine feature turn on by prompt OVLY in overlay 17 , you can disable the overlay command 30,34,38 from OVLY , the midnight will be skip the disable digital phone if you unplugged the phone jack..
Good Luck