Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Chriss Miller on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by wanyph

  1. wanyph

    Problem with Computer Authentication (IAS / Wireless)

    Hi, At the moment we have 2 MX400 running and now I can say that this system was a good decision! We just have about 50 APs (MP372) running. But this will be much more this year! I was at trapeze-trainig in hilversum/netherlands for 3 days. This was one of the best trainigs I´ve ever had. mewi
  2. wanyph

    very slow logon on different subnet

    Hi, Yes, the switch is filteting broadcasts (layer3) Do we need broadcasts? DNS settings are ok. mewi
  3. wanyph

    very slow logon on different subnet

    Hi, I have Subnet A: 172.16.1.0/255.255.255.0 with all servers and many XP clients. All working very well. and I have a new Subnet B: 172.16.2.0/255.255.255.0 Layer 3 switch is connecting the two subnets. I moved one clinet from subnet A to subnet B. When I try to logon, I have to wait...
  4. wanyph

    exchange logging

    Thanks for your information. But I´m searching for a tool that can make some good reports. for example: which user opens another mailbox from which node. mewi
  5. wanyph

    exchange logging

    Hi, My boss is thinking that someone is reading his mails. I know that I can enable logging for the whole server (eventvwr). But that is too much data for me. Is there a way to enable detailed logging for just 1 mailbox?
  6. wanyph

    Problem with Computer Authentication (IAS / Wireless)

    ok, We will get the MX-400 in January. In February I go to The Nethlerland for a trapeze course. mewi
  7. wanyph

    Problem with Computer Authentication (IAS / Wireless)

    Ok, Maybe you´re right, I only told you about my experiences. btw: Are you satisfied with your trapeze equipment? best regards, mewi
  8. wanyph

    Problem with Computer Authentication (IAS / Wireless)

    hi, I am not 100% sure, but we will get our trapeze equipment in some weeks, and we will work with EAP/TLS and computer authentication. (windows 2003). I tested PEAP some month ago, and my opinion is, that the is only username/password authentication. best regards, mewi
  9. wanyph

    Problem with Computer Authentication (IAS / Wireless)

    Hallo, I think, that EAP/PEAPv2 is for user authentication only. I you want computer authentication, you have to use EAP/TLS. mewi
  10. wanyph

    config file error passport8600

    ok, here it is: passport1:5# source /flash/config.cfg syntax Required parameter <integer> = 0 is out of range or no value given Required parameter <integer> = 0 is out of range or no value given syntax errors in script passport1:5#
  11. wanyph

    config file error passport8600

    hi, show ip igmp info doesn ´t work. passport1:5/show/ip/igmp# info "info" not found in path /passport1:5/show/ip/igmp passport1:5/show/ip/igmp# interface ================================================================================ Igmp Interface...
  12. wanyph

    config file error passport8600

    Hi, Thanks for your response. I tried to change the value to "10" But after some seconds it´s automatically gone back to "0" mewi
  13. wanyph

    config file error passport8600

    hi, have a big problem with passport8600. I got this message when rebooting the passport: (on both CPU) software release: 3.2.2.2 "required parameter <integer> = 0 is out of range or no value given" [11/11/05 19:48:06] Initializing 8616SXE in slot #7 ... [11/11/05 19:48:09] Initializing...
  14. wanyph

    Using Machine Certificates with 802.1x EAP

    hi, was it helpful? mewi
  15. wanyph

    Using Machine Certificates with 802.1x EAP

    ok, here is it: Enabling Computer-only Authentication Using the Registry To configure computer-only authentication through the registry, all the Windows-based wireless clients must have the following registry value set: HKEY_LOCAL_MACHINE\Software\Microsoft\EAPOL\Parameters\General...