Caller ID with BC11 over analogue extensions is working with certain patch, so it works, but AASTRA (X-Ericsson) should provide you with SACOS and patch file for this.
Regards
Did any one try before SIP Extension over inetrnet or WAN Network.
I am using AASTRA SIP phones, the extension is registered to the telephony server (TSE 3.2) but the speech is one way.
What should I configure in TSE?? Is it only IP Extensions??
I know well that we have Redundancy on the network and server level in TSE but I would like to know if the below scenario could work.
Do we have hotstandy for the calls in MX-one Telephony server??
Let's say that I have a call (IP Phone)and my TS (LIM1) went down, is it possible for the IP...
Hi,
My system is TSW SP5 and have a problem with caller ID (CLIP)on the operator.
Im using ISDN E1, and no problem with the caller ID over digital extensions but there is a problem with the caller ID on the operator.
(No problem in caller ID on the operator if I am receiving an internal call)...
changed BCAP but the same!!!
Could you please post your parameters (ROCAP,RODAP,RODDP,nutrp) at the three systems also the extension category...
What releases do you have??
Did you do all translations at ystem B as required??
I have already did this and it is the same result.
what do you mean by TRC=R??!!
This is my NUTRP in SYSTEM B
<NUTRP;NUMBER CONVERSION DATA
ENTRY CNVTYP NUMTYP ROU TARDST PRE TRC NEWTYP CONT BCAP HLC
601 1 0 3...
Hi Daddy,
CNVTYP=2 couldn't be used together with TARDST..
CNVTYP must be 1 to be used with TARDST..
Daddy, does the scenario Im trying is acheivable?? do you have some sites with same scenario??
I have done the traces many times before for a transit call ,at the transit switch ofcourse...
system B (TSWSP04):
Route 1 is the PRI T-interface route to system A.
Route 2 is the Qsig route to the telephony server (System C).
<ROCAP:ROU=ALL;ROUTE CATEGORY DATA
ROU SEL TRM SERV NODG DIST DISL TRAF SIG BCAP
1 7130000000000010 4 2110000011 0 30 128...
Hello Daddy,
I tried that in the transit switch but the same!!! I always got 601 when I receive the call at system A (pstn)..
Again my parameters:
<RODDP:DEST=ALL;EXTERNAL DESTINATION ROUTE DATA
DEST DRN ROU CHO CUST ADC TRC SRT NUMACK PRE
2 2...
Hi,
I have TSW system connected with Mx-one telephony server over Q-sig...where the TSW is connected to another TSW using DSS protocol (T-interface).
System A :TSW which works like PSTN.
System B: is the TSW which is in between the two systems, which is connected Qsig with the telephony server...
I have a qsig networking with Alkatel. my parameters as below:
System release:TSW SP5
RODAP:ROU=90;
ROUTE DATA
ROU TYPE VARC VARI VARO FILTER
90 SL60 H'00000350 H'35440000 H'06000000 NO
ROCAP:ROU=90;
ROUTE CATEGORY DATA
ROU SEL TRM SERV NODG DIST DISL TRAF SIG BCAP
90 7110000000000010 5...
Hello,
For testing, I made a new route in the system and added a trunk line to this.
I changed the TRM of route from 4 to 7 (by command ROCAI) , and for each route TRM value I changed the TRM value of an extension from 0 to 3 (by command KSCAC). i.e, a total of 16 options.
Then I made calls...
I typed LSCOP and found the ATTN address is 2... and as you aware that the attenuation value of this address is always 0 db and couldn't be changed...
Any comments..
Should I change the TRM for the extension category??
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.