  1. TioDu62

    Ringing issue

    It depends on the telephne set. Not the system. The Analogue extension board accepts both method of dialing. Check if the telephone has a kind of switch to change fom pulse to dtmf.
  2. TioDu62

    Ringing issue

    Check if the status of the called extension with command SUSIP, maybe has follow me activated. Or just in case dial #001# on it. This procedure is the general cancelation, it will clear any active feature.
  3. TioDu62

    Ringing issue

    Why using Pulse Dialing? This is for very old analogue phones. Maybe your system is set to use Swedish pulse Dialing method.
  4. TioDu62

    Firmware Download MITEL MX ONE MGU

    Hi, I can help with this issue. I do have access to Mitel. Let me know what version your MX-one is running. Some versions of Mx-one can be incompatible with the latest versions of MGU FW. To load it into the board, there are two ways. With command board_sw. To use this option, you need to...
  5. TioDu62

    LPU5 red alarm and PABX hang

    You probably have a HW problem. Hard do say exactly what board is. Can be LSU, DSU, the own LPU5 or even the DC/DC converter from magazine the LPU resides in.
  6. TioDu62

    call list

    Yes. It is the way the feature works for me.
  7. TioDu62

    call list

    Yes, a member of Hunt Group can have a call list in place. There is no restriction. Direct calls to this member will be diverted if call list is active.
  8. TioDu62

    Coonection error on provisiong manager 7.8 SP0

    I did not understand your question.
  9. TioDu62

    Coonection error on provisiong manager 7.8 SP0

    But it does not point an Action to correct the fault.
  10. TioDu62

    Coonection error on provisiong manager 7.8 SP0

    I have been browsing the CPI for Provisioning Manager´s fault location and it said that this case is most probably a "network problem".
  11. TioDu62

    Coonection error on provisiong manager 7.8 SP0

    Have you tried with others Profiles? Try to restart the Webserver in mxone_maintanance in webmanagement, than choose option G.
  12. TioDu62

    Coonection error on provisiong manager 7.8 SP0

    What is the Provisioning Manager profile being used? Profile like System Setup Admin, can´t create extensions.
  13. TioDu62

    Coonection error on provisiong manager 7.8 SP0

    Does the fault ocuur only when trying to create an extension?
  14. TioDu62

    Coonection error on provisiong manager 7.8 SP0

    The PM/SNM SOAP interface is being stepwise replaced by the new Rest APIs in the modernized PM/SNM. The old PM/SNM SOAP interface will be removed once the REST APIs in PM/SNM are fully implemented, for all operations.
  15. TioDu62

    Coonection error on provisiong manager 7.8 SP0

    Is the PM running the same version of your MX-one system? I mean 7.8 SP0.