Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations wOOdy-Soft on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by tigerlow66

  1. tigerlow66

    flash-hook issue

    Hi, Does anyone know how to verify the Analog hook flash timing in BC9 & BC10 system. Thanks in advanced.
  2. tigerlow66

    MD CAS SIGNAL DECODER NEEDED

    Hi, Urgently need an CAS signal decoder for troubleshooting purpose. It's since like SAM Signal trace interpreter only decode SLP60/DECT etc.. but not CAS ELP7. Can someone help. Thanks
  3. tigerlow66

    MD110 BC9 cni85, follow me to common abbreviated number.

    Hi too all, I am having BC9 too. And i need to use CDINI via Abbr No. externally for my extension so that the ECF will only forward my call to external ,when my extnsion did not answer the call afer 6 rings. Can someone tell me where can i download the ptch or the RED(repeated enhanced...
  4. tigerlow66

    How to create new maintenance login user beside root

    Hi, Recently i encounter a funny problem from hicom300 remote login. Symptom : i am able to login via my office desktop pc modem to the system.But when i try to login via my laptop, i always received ' no carrier ' prompt from the remote hicom 300 modem. My other colleges has no problem at...
  5. tigerlow66

    configure remote modem? AT commands.

    Hi, Had encountered the same problem as follow : case 1 : after issued SSSSSSS; but the MD did not responsed with SSSSS via the remote modem. 1.1 Action taken : restarted IPU OK,but for a short period of time only, after that same problem happed again. case 2 : under case 1 condition , some...
  6. tigerlow66

    Dialog Phones

    Hi , can the ordinary 3213 phone be program as an OPERATOR , so that it can enjoys what is in the OPI 3213 phone. Thanks
  7. tigerlow66

    displaying of the non-Latin characters

    To all concerned Currently i had an MD110 BC11SP12 with 2 type of PCB 1.ELU28 ROF1375334/3 R3B & 2.ELU28 ROF1375334/2 R1A I am using DB4222 & DB4223 & DB3212 & DB3213.All the above 4 types of phone is unable to display the letter " p " on the display.Rest of the...
  8. tigerlow66

    SCEXP error on TLU79,but the trunks in working fine

    Hi Whosrdaddy, So far do not encounter any error on HIMDP. Regards,
  9. tigerlow66

    SCEXP error on TLU79,but the trunks in working fine

    Hi whosrdaddy , Thank for the info. I will re-program the TLU79 to slot 1-2-40,if still has problem in getting the syn.I will replace the TLU79 board. Best Regards,
  10. tigerlow66

    Is there a way to know where is the ECF destination on MD

    Hi duvel, Is Power OFF&ON & RFEXI about the same.Both will caused all incoming & outgoing calls to dropped. For info,the MD use to be OK,but sometimes the PIckup is not working. Thank You.
  11. tigerlow66

    SCEXP error on TLU79,but the trunks in working fine

    Hi cccjay55, Does this means i do not need to do the scexi, the isdn2 still will work.So what is the purposes for the scexi Thank You.
  12. tigerlow66

    SCEXP error on TLU79,but the trunks in working fine

    Hi, SCEXP; EXTERNAL SYNC RECEIVING LINES DATA MASTER LIM STATUS FIRST CHOICE 1-2-42-0 INTERNAL SYNC ERROR SECOND CHOICE 1-2-42-2 OK THIRD CHOICE 1-2-42-4 OK As i install the TLU79,when i initial the...
  13. tigerlow66

    Is there a way to know where is the ECF destination on MD

    Hi, Need some help for the following case. I had encounter ECF not working for a while,until i restarted the whole system. My MD is an BC10CNA137.When i used SUSIP on the extension,it only shown as ECF. & btw is MD system always need to do Power OFF&ON to re-initialize the data ,inorder to...
  14. tigerlow66

    Hunting over BRI

    Hi Matt, For Trunk hunting ,is normally provided by the service provider ( Public Exchange ).And in this case circular hunting is better then pilot huntig if anyone of the BRI is out of order. Hope it help. tigerlow66
  15. tigerlow66

    BP R13 remote modem issue

    Hi Norrman, I had flash out all the old data with an COLD START on the system. Right now is getting wrost , both Remote login via CO & Extension is able to connect to the system,but was kickout by the system with the below error 1.Error system infomation could not be retrieved. & 2. System...