A guy that had control over a couple of fairly valuable windows servers got fired from our company. They have OEM installations of 2008 R2 Enterprise, and 2008 R2 standard. None of the passwords alleged work, all the software is missing (including the product code key information); the product...
Thanks very much for your responses, AD replication sounds right. It has just never taken that long. We are still on a 2003 domain controller, so not deleting the account is the only way to go.
A domain user's account was deleted by accident, and then recreated. Some of the user's permissions to applications and/or data took about four hours to work properly. Does anyone know why some of these permissions took so long to start working?
I have a 2610XM router that loses its running configuration every time the router is turned off, or reloaded. The "copy run start" command does not help. Has anyone experienced this?
Here's the sh diag, (notice the unknown WAN daughter card). I think what I need here is an IOS upgrade.
Slot 0:
C2610XM 1FE Mainboard Port adapter, 2 ports
Port adapter is analyzed
Port adapter insertion time unknown
EEPROM contents at hardware discovery:
Hardware Revision : 4.0...
Here's the sh ver:
sh ver
Cisco Internetwork Operating System Software
IOS (tm) C2600 Software (C2600-I-M), Version 12.2(8)T5, RELEASE SOFTWARE (fc1)
TAC Support: http://www.cisco.com/tac
Copyright (c) 1986-2002 by cisco Systems, Inc.
Compiled Fri 21-Jun-02 08:50 by ccai
Image text-base...
I have a 2610XM that boots fine w/o the T1 WIC. When I install the WIC, I get the following message:
"Uknown WIC in slot(0/1), WIC has an unknown ID of 0x52"
"00:00:10: %SYS-2-GETBUF: Bad getbuffer, bytes= 68444513
-Process= "Init", ipl= 0, pid= 2
-Traceback= 80378168 8081667C 80816568...
When creating a permit statement in an access list where ports are also being specified (eq 3000), what is the syntax to allow multiple ports in numerical sequence?
Would this work (eq 3000-3009), or would you need to create a permit statement for each port?
Thanks,
Tom
I have a Catalyst 5500 switch that recently started resetting all four switch port modules simultaneously. This is happening once every couple days to two weeks. Does anyone have an idea what might be causing this?
We got this error today; has anyone seen it?
"The stored procedure CreateSQLTmpTable returned the following results: DBMS: 12 Great Plains: 0"
Thanks,
Tom
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.