  1. sunweb

    Hicom Vs. MD110 QSIG

    Hi Hank. You can try protocol ECMAV2 in AMO TDCSU but remember to adjust the LWPAR. I wait to have helped. Regards SunWeb
  2. sunweb

    Hipath 4000 cpid and inband dtmf problems... Help?

    Hi, which the version of HiPath 4000? Regards SunWeb
  3. sunweb

    Hipath 4000 install

    Hi phones1, what you really need? I can help, but either more specific. a default username & password is ROOT and HICOM. Regards SunWeb
  4. sunweb

    CDR format for Hicom 300 E v6.5

    Hi Joe, You can change the format of the CDR's of Hicom 300 in AMO SELG, but either more specific in relation the version of the Hicom 300E,ok? I wait to have helped. Regards SunWeb.
  5. sunweb

    Hicom Vs. MD110 QSIG

    Already it tried to connect through ETSI? Which model of Hicom you use? Greetings
  6. sunweb

    New to Hi-Com/Hi-Path/Hi-Path Procenter

    Hi Fred, reference materials on ACD type HiPath Procenter I do not know will be gone to find so easy, until I go to help and to verify inside of the site technician of the Siemens and if to find sending for email, ok? But I recommend you to request consultant Siemens technician to assist it...
  7. sunweb

    load profil

    Hi zizoudevinci. if I understood, you I want to have functions of its telephone and its profile in other telephones of its company, is this? This can be made by AMO PERSI, where using a code declared in the WABE and plus a password declared in the PERSI, you it will have all the functions of its...
  8. sunweb

    HiPath programming lead?

    Hi hooligan71. It uses a handle standard of routers Cisco and plus an adapter DB25 for RJ45. In case that it has in its HiPath 4000 a HubC plate, HiPath 4000 UV1.0/ UV2.0.. Atlantik LAN connectivity, uses only straight-through patch cord, both ends must be wired EIA568A. Best Regards Josué
  9. sunweb

    Accounting

    Hi, you must use AMO FBTN to register in cadastre the trunks in the HiPath 4000 after this step accounting must be made in a external system of billing. I wait to have helped. Greatings
  10. sunweb

    Accounting

    Hello, You must use AMO's FBTN to register in cadastre the trunks in the Hicom 300 or HiPath 4000, or still the number of the lines in the Hicom 150 or HiPath 3000. After this step accounting must be made in a external system of billing. I wait to have helped. Greatings Josué
  11. sunweb

    HiPath 4000 - Checking for trunks down

    It forgives uses the type below: It will list all the circuits that are down in HiPath 4000. Trunks and circuits type slma24, stmd2, stmd3, slms, slmo,... DISPLAY-SDSU:STATUS=DEFIL&UNACH&DEPLOCK,TYPE=PEN,LEVEL=PER3; I wait to have helped Best Regards Josué
  12. sunweb

    HiPath 4000 - Checking for trunks down

    Hello, you use AMO SDSU, but type: DISPLAY-SDSU:STATUS=ALL,TYPE=PEN,LEVEL=PER3; Greatings Josué
  13. sunweb

    Running a cronjob on a HiPath 4000

    Hello Mikerault, you to use AMO CRON, the "manager" of tasks do HiPath 4000, use sw comwin and inside it undoes types CRON + ctrl + tab. Will be all the options you gave AMO. Greetings Josué
  14. sunweb

    Regen configuration of Hicom 300

    Use MACRO!
  15. sunweb

    ComWin 300 Commands?

    Hi Teletim. You can use the following AMO START-HISTA:RTYPE=SEARCH,STIME= Greatings Josue