Yes it will work, but don't exagerate with distance...
The pinout is the same as TLU76... the four pin on the right side of the connector.
I hope is clear.
BR Simone.
Where MML commands can't, linux can. MXONE power.
Are you sure that you arrive on the BP modem extension? Have you did any traces on MXONE or BP? if yes, can you post it?
Wich kind of connection there is between MX and BP ? (QSIG/IPTrunk/etc)
BR Simone
Where MML commands can't, linux can. MXONE power.
Hi ffmartin, the ISDN cause 28 mean "invalid number format (address incomplete)." and this is the correct behaviour in this case ( -> incorrect setup <- callproc <- disconnect )
Maybe you have properly setup the correct number length on the BP: first of all i think you have to use a PNR and...
Hi Matt,
i had the same problem, but i can say to you that is a general problem related to any H323 client. If you call towards hunt group or towards a user with activated voice mail, seems to be that mx-mess didn't 'hear' anything.
First of all you must set priority on G.711, because mx-mess...
What do you get on DTS display? The feature code is correct? Is the same if you try from a DTS or an ATS?
Where MML commands can't, linux can. MXONE power.
if you must change only the default gateway, you don't need to change any config file related to MXOne Appliance. You only need to change it in Yast.
Otherwise you can do it from command line for just in time config:
route del default gw xxx.xxx.xxx.xxx dev eth0
route add default gw...
why you can't connect directly MD to LAN for example with ITG, so you can have all services like name and number presentation with full User to User integration such in a real QSIG? More over if you upgrade exchanges (is sufficient BC11 but prefer last release such as BC12.2 or TSW, formerly...
for proof of concept, we have tried in our lab without knowing any password to decript it directly reading dump data from HDU and we can decode it succesfully. obviusly you must have physical access to the HDU.
in general with 3rd party devices you have only basic call, nor names or anything else, only number presentation and not ever.
Take in mind that MD110 ELU32 has also a limitations... it can handle only 30ms RTP packet but when in "Terminal Capability Exchange" says that can handle many other. So...
take a look to command 1420, 1421 and 1422. I think you must 'describe' your disconnection tone from AXE and tell after how much time the tone is detected do you want the BTU disconnected... (excuse me for my english...)