dont get 2 technical jay944 as ive not touched an md110 since nov last year md whats an md oh i know someone who trys to run a successful company but fails drastically making a quarter of the staff redundant humm sounds fammilar that
thiers no remote test you can do to see if md can see extn if the extn is ringing when you dial it more then likely a cabling/socket/phone fault site visit req im afraid
the quickest way to cure this is to locate the lpu in lim 1 mag o and press the pushbutton once dont do it twice pterwise the lim will fallover and reload itself
ive also had this as well if you have multiple links to lim 2 make the top link is the signaling link when you do a gjlsp if not change it to the top link by blocking the other link temp gjbli:gsside=,gsmult= when comex back executed unblock the link with gjble:gsmult=,gsside=
also have you any...
its klp1o thats the letter o that you need to restart but be carefull as this will cut all digi calls in the llim not just the 1 card the command is rfpui:lim=,unit=klp1o;