Can anyone tell me what range of udp ports should be open for any given network-region. I do not want to open too many UDP ports and if I choose a 100 can it be any range?
Thanks
Has anyone seen an issue where thousands of packets per sec are attempted to be exchanged between an IP phone and CLAN over a VPN. VPN dropped out and firewall blocked ports devices thought they had connections on. This caused some major issues and I havent come across it before. I understand...
If a split is used without a vector but with measurements switched to external(cms) do I route calls just to the hunt group/splt extension?. Will this just do the same as routing via a vector(ie queue to xx) but without there being a queue? How would the stats work in this instance? There...
We are using a Nice Matrix Logger to logs calls over a number of E1 circuits. We now want to record some internal calls as well. To do this we route calls over tie trunks via the matrix logger and back to the switch. The tie trunks and call transfers work ok but I'm not sure if its possible...
Dwalin,
I have set it up and the signaling groups are in service!
However when I make a call it goes across the two ds1s/trunk groups(checked via cms), arrives at the right phone but there is no speech heard from either end. No sure if this is down to the supp protocol on the signalling group?
Dwalin,
I tried to create the signalling groups and the supplementary protocol defaults to A. I believe it should be set to B for QSIG basic signalling. However it seems we done have this as a customer option:( You mentioned that the primary d-channel should be the 24th timeslot. Normally I...
I realised my mistake just after my last post. I made a cable up switching the two pairs you mentioned 1,2 & 4,5 and the test 138 passed! Thx
Did you say that I do need a signalling group with this?
I used a cross-over cable to connect the DS1s and I do get a fail on the test 138? I am not connecting via the Matrix logger yet. I just wanted to test the ds1s back to back first.
one more thing. For a tie group what kind of signalling group is needed , if any? I'm getting 1281 errors and from the Maintenance manual it suggests a loss of signal?
Thanks Dwalin.
We do actually use service observer but we need to scedule recordings through the logger. This infor will help a lot.
I have the settings for the tie trunk group but I'm not sure what settings to use for the DS1s . Could you help with this?
Thanks
I'm using a NICE matrix logger trunk side and need to record some internal calls. The only way I can think of making this possible is by routing the internal calls out through one DS1 which is connected to the matrix logger and then back into another DS1. I think it will be a tie trunk set up...
Is it possible to remove the facility to Log off an extension form a 4620 IP phone? Phone users are pressing the Options button and logging the phone off and I'd liek to stop them from doing this.
Thanks