Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations bkrike on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by safron

  1. safron

    GS clock errors. TSW

    Thanks for responding Daddy. I now have a class 4 (EC115) relating to a link in Lim4, could this be the cause of the clocking errors? Alarms & Lost signal also attached. <SCEXP; EXTERNAL SYNC RECEIVING LINES DATA MASTER LIM STATUS [MASTER SCOPE] FIRST...
  2. safron

    GS clock errors. TSW

    Made my prints easier to read. :) The 'Incomplete clock ordering in GS error' (bit=6) moves around all GJ links. Any ideas? <SCICP; MASTER LIM/GSM CONFIGURATION DATA MASTER 2ND MASTER 3RD LIM GSM LIM GSM LIM 2 0 1 3 <SCEXP...
  3. safron

    GS clock errors. TSW

    Hi Guys, Been a while! Having issues with GS clock errors. Not sure if it's due to a bad external clock source or not. I have no alternate ISDN for the external source. I have turned off duplicated GS to simplify trouble shooting. As was seeing errors on GSside 1 also. GCU has been replaced...
  4. safron

    TSE 4.1 sp5 Lim 1 repair - MP issue.

    Hi, Thanks for the info and sorry for the delay in reposnding. I did not edit the login-config xml file, instead I have un-intalled MP and re-installed on Lim1. After recreating the subsystem I was able to click the subsystem and be connected straight through to MTS (Proving this account)...
  5. safron

    TSE 4.1 sp5 Lim 1 repair - MP issue.

    Hi All, Since making a repair of lim1 (due to faulty ASU - drive) I am now unable to use MP. Each time I try to intergote the system, eg: view extns. I receive 'Authentication error'. I think this is due to conflict in MTS username/password. On Lim1 rebuild Aastra/Aastra was used which...
  6. safron

    Possible Digital / Pelpi corruption??

    Guys, Assigning a PELPI for extn xxxx, then ending this PELPE rectified the issue as i'm now able to end the digital ok. Thanks for the prompt responses all the same. :) Saf!
  7. safron

    Possible Digital / Pelpi corruption??

    Hi All, I'm trying to end a digital extn but receiving error 'Not accepted DIR xxxx personal number' No personal number currently assigned for this extn. I will try to restart PEP, and relevant KLP units in the Lim that digital resides after hours but was thinking me need to be SACOS'd? Has...
  8. safron

    TSE / Mx-One Messaging fault.

    Hello, I have TSE v3.2 sp1./ Mx-Messaging 4.2 (7.90 build 256). I wondered if anybody has come across this, or is able to assist. Issue is, intermittently when a VM msg is left, the message when played is 'Garbled' (Underwater effect). When message is played back from CX folder, using media...
  9. safron

    No Message wait indication- OneBox 4.2 (Mxone - TSW)

    Hi, I have an issue with MEW across QSIG (Standard QSIG params) OneBox 7.92 build235.(SIP integration) Mx 4.1 sp4. NOTE: MEW on Mx-One ok. Message waiting indication fails on extns intermittently across QSIG to TSW.sp8. (SUSIP does not show MEW act) Diagnositc on Onebox MWI server show MEW...
  10. safron

    TSW: Analogue line lock out. Need to send signl to clear.

    Hi HIMDP, Yeah sorry, cut and paste gone crazy there.[smile] Definately SG rather than FT in future for this particular issue anyways. Cheers!.. Saf
  11. safron

    TSW: Analogue line lock out. Need to send signl to clear.

    This is an interesting post - thanks!
  12. safron

    TSW: Analogue line lock out. Need to send signl to clear.

    Hi all, Normally i would use FTSAS, FTSSI to clear this linelock. (if not linefault) usually clears it. This was when i had a mult calculator to convert equ to hex. :) Can anybody assit with this or provide a mult calculator, so am able to use...
  13. safron

    SACOS required for ADN - Busy... tsw sp7.

    himdp, dont worry, i again cleared busy state, ended the ADN and re-assigned all now ok thanks for you help. Saf.
  14. safron

    SACOS required for ADN - Busy... tsw sp7.

    himdp, Unfortunately the line state of the ADN is again showing busy, i guess once called its state changed. I tried to restart DER & KLP1T in the lim of the ODN to no avail. I guess a SACOS would be required after all? If anybody could assist with the this i would appreciate it. Thanks Saf.
  15. safron

    SACOS required for ADN - Busy... tsw sp7.

    himdp, This worked a treat!! For furture reference how did you work out the last data byte... (2-00). Obviously my linestate pointer - 02c5 Could you use the same process if traffic state - KLP1T was locked up? If you have any information on clearing busy or linelock status, in this manner...

Part and Inventory Search

Back
Top