Yes, I have tried a lot of combinations.
I can force the call up the VTRK to the NRS but get it rejected.
On the NRS I have tried this config:
Service Domain = customer.com
L1 domain = myCompany.com
L0 domain = MyCDPDomain
Enpoints = siteA and siteB
and
Service Domain = customer.com
L1...
Hi,
1. Yes it is
2. Idle reg'd
3. The SBO is defined with the MO in Gateway endpoints
4. Can't do IP at MO to TDM on SBO, will try SBO TDM to MO IP tomorrow
I am now pretty sure it is call types (SBO dials AC1 + XXX, = AC2 + ZDP + XXX and NRS is not understanding it), I wasn't sure if the SBO...
I am trying to get SIP trunking to work between a MO and SBO.
I can route the call from the SBO local exchange to the MO but can't route it back up to the SBO.
The ZDP/RLB/DMI etc are all OK, but the call never hits the Vtrk Dch - even when I force it with an acod..
Anyone had this or can...
Hi,
you can use a US robotics courier modem.
That supports remote and local passwords. only 8 characters though, but it is case sensitive.
you can set it for both remote and local passwords
Cheaper than £800 too.
YES it can.
A 61c to PII upgrade is supported as long as you go to Rls 3 software.
The D and E cables are required to allow the both half groups to communicate not for the CPUs. (The PII card cages has the provision for the D & E cables) The PII CPU's only sync through the LAN. I have just...
I know about MG/SG but like I said I wouldn't want to as a 61 is a 1 group switch (refering to FNF). My question was can a 61 be upgraded to a CP PII 1 group (i.e. are the D and E cables the same to connect the buses, etc). According to MERL3 it is not supported unless it is a 61/61c to 81c...
Is it possible to upgrade a 61c CP2 to 61c CP PII without FNF? I know the upgrade is supported for a 61/61c to 81c PII with FNF as it says so in the NTP's but no reference to keeping it a 61c.
I know that there is not much point either - I mean buying a super CPU for a 1 group switch and all...
Yes, tried all that. it is an issue with the s/w. Like I said Nortel are upgrading for free (61c 22.46 - rl3) as they made a mistake... well for sl1 anyway needs 25.40 or later..
SL1 won't work unless it is 25.40 or higher. if you try, with either a DCHI or MSDL on lower software you will get BC errors. Works straight away if you have the right software level. I had to use a Mini instead.. Nortel told me it would work and it didn't so they are footing the bill for the...
You can configure the ITG without OTM by taking the flash card off the card and putting in your laptop if you need to (corruption or you can't/don't have OTM)
It is much, much easier if you have OTM as you need to know what you are doing. ITG expert guide required. I did it once but it was a...
This is a problem for calls coming into the M1, not out. I can call out so the TGAR/NCOS are fine.
PRI214 is a layer 1 protocol error - fix is to call tech support :( I am wondering if there is a patch or it won't work with a DCHI card and needs an MSDL. I got this working with an opt11 on...
Hi, the route/trunk is programmed as a tie.
I am sending 9123 from the BCM to route out from the M1 to the CO, 123 is the speaking clock in the UK.
All other numbers are the same (PSTN and local DN's). Can dial them locally (on M1) but can't send them from the BCM.
Hi,
I know that BCM to M1 is possible using SL1.
I have implemented it on a RLS 22.46 opt61 and can only make calls from the M1 to the BCM but not the other way.
When I try to call I get the following message:
PRI214 DCH: 13 DATA: 00000003 PROGRESS: ORIG ADDR IS NOT ISDN
CALLED #:9123...
Thanks for that.. I have it from ascom (finally) that these are the pins below. The CIU takes it's power from the +AUX and -AUX. It is different to that of the 2250 which uses the 3rd TN.
25 pair cable
from console
to MDF DB 25 on CIU
26 (w-bl) 14
1 (bl-w) 2
27 (w-or)...