Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Wanet Telecoms Ltd on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by QcTek

  1. QcTek

    Schedule M3900 firmware upgrade

    bigindian65, Thank you, I'll give that a try !
  2. QcTek

    Schedule M3900 firmware upgrade

    Ok I kept on looking for information on firmware upgrade on this forum and found this : FAQ798-6394: Scheduled download So that answers my question quite well, but I'd still like to know if someone has a clue as to how much time it should take to upgrade 2000 M3900 phones ? Thanks again
  3. QcTek

    Schedule M3900 firmware upgrade

    How should I do if I want to schedule a weekend firmware upgrade for every M3900 phone we have in the PBX, and how much time will it possibly take, given the fact we have about 2000 digital phones ? I read the following tip in another thread, but I'm not sure how I should apply this : LD 97...
  4. QcTek

    Distinctive Ringing by DN

    Hi everyone, I already know about the CLS DRDA that allows distinctive ringing by DN, but this option only allows to have the same ring tone, with a different cadence, which is set with the DNRI or DNR0 options Given a phone, for example a M3903, with 2 DNs, say 5050 and 5656, i would like to...
  5. QcTek

    Resetting Nortel 1120E IP Phone

    I was able to test it on a I2004 and it worked ! I'll get the chance to test it on a 1120E next tuesday, but I suppose it'll work too ! Thanks for the tip !
  6. QcTek

    Resetting Nortel 1120E IP Phone

    Hi, I was wondering if there is a way to reset a 1120E IP Phone without disconnecting the power ? Thanks!
  7. QcTek

    CLID, multiple HNTN (area code)

    I tried with the clid entry as follow : ENTRY 2 HNTN ESA_HLCL ESA_INHN NO ESA_APDN YES HLCL 8663505228 DIDN NO HLOC LSC CLASS_FMT DN And when I placed a call with a set using the clid #2, the number displayed was "613-866-3505" So it is still using the HNTN from the...
  8. QcTek

    CLID, multiple HNTN (area code)

    Well, in my case, let's say I have about 120 sets for which I would want to use a clid entry that would allow them to send for example : "866-350-5228" on outbound calls instead of displaying the default area code(HNTN), in this case 613 (area code found in clid entry 0 and 1). So if my HLCL is...
  9. QcTek

    CLID, multiple HNTN (area code)

    Hi, I'd like to know if it's possible to use multiple HNTN in a single Opt81c system ? For example, if i have the following clid tables : ENTRY 0 HNTN 613 ESA_HLCL ESA_INHN NO ESA_APDN YES HLCL 523 DIDN YES HLOC 180 LSC CLASS_FMT DN ENTRY 1 HNTN 613 ESA_HLCL...

Part and Inventory Search

Back
Top