Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations TouchToneTommy on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by PEDZ118

  1. PEDZ118

    Autoexec will not open switchboard

    I have sorted this problem by moving it from my 2000 server to an xp pc, recompiling it and repair/compact. When uploaded back to the server it works fine. Bit of a strange one. Just one of them microsoft things.
  2. PEDZ118

    Autoexec will not open switchboard

    Yes, It has been set as startup form all along, thats why it is weird why it just suddenly stopped when i was importing forms with no connection to the switchboard at all.
  3. PEDZ118

    Autoexec will not open switchboard

    Ive got a large Access front end that i have imported some new forms and queries into. I can open all forms including the switchboard fine from the database window but as soon as i close the mdb and try too open it from a shortcut in a startup situation it fails. I am getting the window that is...
  4. PEDZ118

    Privelege error when tracking

    We have MS CRM 3 and are running the outlook client on outlook 2003, When certain users try to track mail they get an error that says they do not have priveleges to track the item. If they click the continue anyway button the item is tracked in crm so the message is wrong as it does it anyway...
  5. PEDZ118

    How to change code so that the autonumber is returned from sql 2000

    Thanks very much PHV. the .bookmark .lastmodified now works I had the date/time field incorrectly set up on the new SQL table.
  6. PEDZ118

    How to change code so that the autonumber is returned from sql 2000

    no lines are highlighted. It skips out of it and shows the prompt box over my form, when i open the editor it has stopped. ive put stops in it and it gets to the .update line then when i run after that and the above happens. Pretty strange.
  7. PEDZ118

    How to change code so that the autonumber is returned from sql 2000

    Thanks for the reply PH but i get the same "ODBC CALL FAILED" message.
  8. PEDZ118

    How to change code so that the autonumber is returned from sql 2000

    I have many good size applications that have been running with an access back end up until now. I am in the process of preparing the access frontends so that we can run them on the sql server 2000 back end that i have created. I am having particular trouble with situations where myself and my...
  9. PEDZ118

    Several Usernames And Passwords To One Account

    I have a terminal in my factory that i need 8 different users to access using a microsoft fingerprint reader. This requires them all to have a normal xp username and password. I want all the different logons to go to the same account, ie the same application that i will have running from a...
  10. PEDZ118

    Bring A Subform To The Front With VBA

    Thanks for the reply Managed to do it in the end by enabling the required form and disabling the other one combined with making the required one visible and both not visible by default. Cheers
  11. PEDZ118

    Bring A Subform To The Front With VBA

    I have a form with 2 subforms on it that are placed with one on top of the other one. Depending on a variable i want either one to come to the front however i cant get the one that is behind to come to the front and be able to edit the fields on it. I have tried using .setfocus on the one i...
  12. PEDZ118

    Moving offscreen windows

    The easiest way to resolve this problem is to go into "Display Properties" then Settings and click on the second monitor on the diagram. Untick the "Extend my windows desktop" Tickbox. All windows should now open on the primary monitor.

Part and Inventory Search

Back
Top