Is the agemt using a headset key?
There is an issue in some versions of the 8100 where the user can let the outside party release but not press the Headset key to let their end go. The ACD reports the agent as idle (because of the trunk release)but the 8100 sees the agent off hook because of the...
You would need to set another mode (E.g. Night) to have all stations ring with MB 4-02. To have all stations ring place the system into night mode. Of course if you are already using night mode to go to VM then the only other option woiuld be to try overhead ringing through the paging with a...
The Electra Elite IPK is no longer being sold for new systems by NEC and only parts are available. The latest version is the IPKII and now just released is the SV8100 which is the latest. The older Elite IPK does support VOIP but it will be complete end of life ion few months and NEC will not be...
The difference is when the digital stations call out the CPU pulses the DTMF to the carrier. When a single station calls out without LCR it is DTMF directly from the station device itself. Sometimes the first digit is lost from the single line as the PBX is aquiring the trunk for the outgoing...
I've seen this twice before and it has to do with the VEN memory assignment when the station is assigned. I think I had to do a B load and then shoot the database back in via the script editor.
I have one. It's an actual Dterm handset with a mute switch on the underside where you can easily press it with your index finger while on a call. There are 2 models. A push to talk and a push to mute. Don't know what the part numbers are I'll look that up.
The D CM's are only for the AP00 if installed in the remote site so don't worry about them.
Just make sure you have 08>800>0, 08>378>0, A703>CCH#>0, and A704>CCH#>PC of main site. EC6 it and some times it needs a kick in the bum (reset CPU) to get it going.
Take the VM out of the picture. Be the VM I always say.
Answer the trunk call at a station and transfer just as if you were the VM and release. Does it then go to the mailbox on a forward?
Make sure that timer classes are not set for the stations in MB 4-71.
The cheapest one of course. I have no idea of pricing but I would guess that the 8IPLA would be best or you may be able to locate an older 32IPLA somewhere (pre-loved). But by the sounds of it you would not need more than the 8 PAD channels.<br>
But I cannot stress enough how you MUST have a...
Yes Remote PIM via IP (DMR) will work fine as long as you have a reliable connection between with less than a 300ms delay round trip between sites.
the older T1 DAIA and DAIB cards are not supported on the NEAX IPS since the Remote PIM feature was released.
Your spare MP and PIM will work at the...
I have worked with NEC for many years after working on a range of other systems. I have also taught many classes on the product and the most common reponse I see is the respect for the functionality and flexibilty of the system while at the same time concern over the complexity of the...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.