  1. papad

    Replacing tapedrive Autochanger/Networker

    Hello, I have an autochanger (4560SLX 0429|Autochanger (Jukebox), \\.\Changer0) with 2 tapedrives. Till now I had one LTO1 and one LTO2 dirve. I just replaced the LTO1-drive with an LTO2-drive. The drive is visible in window and with inquire, but in the gui of Networker stays as LTO1. How I can...
  2. papad

    retention policy and expiration date

    Hi 605, -I am running NW 6.2. - nsrck -X I had already used. - I think that I can conclude that I have a bug. Thanks a lot for the support.
  3. papad

    LINK-4-ERROR

    The hosts are Neoware thin-clients and they have an integrated netwerk-adapter. The netw chip is: Realtek RTL 8139C. Any experience whith this chip above in comb with 3500 switches? Cheers
  4. papad

    retention policy and expiration date

    Hello, - new2me: The browse policy can never be longer than the retention policy. So my problem is somewhere in the retention policy... - 605: I used the mminfo command you suggest. I see several clients with a retention policy of 1 year. The problem is that I cannot find the wrong...
  5. papad

    retention policy and expiration date

    Hi 605, I tried: mminfo -a -r "savetime, ssretent, name" but I don't get the name of the clients. So I can't find the clients with the wrong retention policy. I don't know if I understand goed what you are writing about the server's client.. Can you explain with more details? I have one...
  6. papad

    LINK-4-ERROR

    I have thin-clients on the switchports. I checked the duplex status. The switch-ports are full duplex and the thin-client autonegotiating. I tested with a thin-client with full duplex. The errors are the same...
  7. papad

    retention policy and expiration date

    Hello, I have a retention policy on my day-tapes for 1 week. But the tapes are geting a expiration date for over one year. I cheked the retention date of all clients several times. I cannont find any client with 1 year retention policy. Any suggestions? Thanks
  8. papad

    LINK-4-ERROR

    Hi, The duplex status is OK. Yes, I mean crc-errors. I have input and crc-errors on almoast all f interfaces. Thanks again, papad
  9. papad

    LINK-4-ERROR

    Hi, I have a problem on a 3550 switch. On almost all I get the message: Link-4-error: the interface is experiencing errors. With sh interface I see input errors and cdr-errors. I changed the cables, and the switch. The problem remains the same. Any suggestions? Thanks, papad