  1. nOrtler

    Brand new Fortron EP650VA constantly in bypass mode.

    You definitely have a "stand-by" or a "line interactive" UPS. As mentioned by Fred, these types of UPSs pass line power to the load directly while normal line voltage is present. The line-interactive is also a stand-by, however it's output adjusts a few steps below and above it's nominal voltage...
  2. nOrtler

    I2002 power supply

    there are two types of the 2002: 1. a dual power unit that is designed to run off PoE (at 48VDC) as well as 16VAC, which gets converted to 48VDC by a power module "daughterboard" in the set itself. 2. a PoE set only - labeled 48VDC. This set also has a power adapter jack, but no module inside...
  3. nOrtler

    VoIP 1140E external power questions.

    Hi 1460, not quite sure I understand your question. PoE (power over ethernet)capable switches using the 802.3af standard are able to supply up to 15.4W per port. A newer, future standard called PoE+ is being worked on and will able to deliver up to 56W per port. Hope that answers your question.
  4. nOrtler

    VOIP 1120E +1140E Time off-weird issue

    I know i2002 and i2004 phones only update their time every 4-5 minutes from the switch. Have you seen this update duration on the 1120s as well?
  5. nOrtler

    ADL pause on a i2002 IP set

    Hi folks, wondering if anyone has insight if there is a way to insert a pause in a ADL key, for using passcodes and such. The setup is: i2002 / i2004 sets Succession 4.0 OTM 2.20.78 Pause works just fine in the Personal Diectory of the phone (Pause in inserted using a softkey that inserts a...