  1. northwick

    Mapping luns to DMX FA for HPUX

    Hi I am mapping luns to a DMX FA for an HPUX host. The host currently has luns from a symmetrix 5 presented. When I map luns to the DMX FA should I use different VBUS, Target entries then the currently mapped luns on a symmetrix 5.
  2. northwick

    mirror limitation

    looking at clones rather than having bcvs for multiple mirrors. Allows for more copies. Any thoughts/experience on symclones.
  3. northwick

    mirror limitation

    is there any way to get around the 4 mirror position limitation on a dmx.
  4. northwick

    Lun 0 Linux

    Is lun 000 still required for RHEL to scan all SCSI devices on the emc array
  5. northwick

    SRDF and BCVS

    yes exactly, The R1 standard is also in sync with its R2. Can the BCV that is 2-mirr and in addition is R1, be srdf'ed to an R2 BCV 2-mirr as well.
  6. northwick

    SRDF and BCVS

    Can you have and R1-2way-Mir-BCV established to an RDF1+Mir. Also the RDF1+Mir is in sync with the RDF2+Mir.
  7. northwick

    Connectrix Manager 7.02 Address ID error

    Running Connectrix Manager 7.02 with Mcdata switches. I have a host attached to a port which posts a large number of 'Address ID Errors' as seen via CM7.0.2 Any idea on how to troubleshoot this error. Cables have been checked.
  8. northwick

    HBA not logged in on FA

    emulex
  9. northwick

    HBA not logged in on FA

    www is logged in to fabric / switch port port is listed
  10. northwick

    HBA not logged in on FA

    mcdata switches. will have the fibre analysed
  11. northwick

    HBA not logged in on FA

    difficult one as wwn is logged in on one FA already. FA settings for the 2nd FA are ok for windows hosts.
  12. northwick

    HBA not logged in on FA

    Have checked lun masking - all is correct.
  13. northwick

    HBA not logged in on FA

    Have an hba zoned to 2 FAs on a DMX. On one FA it is logged in successfully i.e Logged On Identifier type Node name Port name FCID In Fabric wwn Fibre Null Null 10002 Yes Yes On the 2nd FA its is not logged in...
  14. northwick

    ITC- Restore from second copy

    The images for the original primary do not exist. Different retention levels. Does the duplicate automatically become the primary in this case
  15. northwick

    ITC- Restore from second copy

    I have used ITC to create a second copy of the backup. The primary tape is no longer available. How can a restore from the secondary be handled. Is this automatic within netbackup of does the secondary have to be made the primary.