  1. nelsonherron

    ILMI fails on 7010/RSP w/ SNMP-3-BADOID: Error

    THe issue turned out to be a bad bus termination at the RSP7000 chassis interface. A new CI cured the problem. Had to buy a new router, too, but it only cost about the same as the shipping. Scary how much UPS makes off eBay.
  2. nelsonherron

    ILMI fails on 7010/RSP w/ SNMP-3-BADOID: Error

    I have gotten a little further than the last time with my ATM/SNMP-3-BADOID: error. It seems that this error is generated when ILMI attempts to start on my 7010/RSP7000 running 12.2.7 IOS equipped with a CX-AIP-SM 155 MM card (73-1188-03 rev B0). The card works properly in a 7007 w/ RP1...
  3. nelsonherron

    "Show running-config" and "show config"

    I have books that say the config and the running-config are the same. However, whenever I make changes to the running-config they are not reflected in the config until I "wr mem" or "copy run start". Therefore, I believe it is appropriate to say that the "config&quot...
  4. nelsonherron

    RSP7000/AIP gives SNMP-3-BADOID error

    I have a 7010/RSP7000 (no CI) that runs fine except for the ATM card. When I plug in the MM cable from the switch I get a "SNMP-3-BADOID: ATTEMPT TO GENERATE AN INVALID OBJECT IDENTIFIER" message with a TRACEBACK string. It is running 12.1.18 boot and 12.2.7 IOS, 128 MB mem. I have...