Recent content by MarkATaylor

  1. MarkATaylor

    as 400

    The process is (more or less) outlined in the Service Guide, I think the Backup & Recovery Guide also covwers this. You can IPL from CD (I_Base_01) enter Dedicated Service Tools & format the drives. Takes a while. You could also do a Manual IPL from Disk, and format each drive (except for the...
  2. MarkATaylor

    Splitting up AS400 DASD into 2 ASPs... pitfalls?

    I don't believe there EVER was a case where a program couldn't read data from another ASP, (if there was, it would have had to be before V3). Anyhow... I guess the question would be, what are you trying to accomplish by creating seperate ASPs in the first place?
  3. MarkATaylor

    AS/400 Twinax controller device limit

    You can physically connect 56 devices (8 ports, 7 addresses per port) but IBM only supports 40 active devices at any one time. I believe 'Active' is defined as attached to a job; in other words, a user signed on to a workstation, or a printer varied on with the writer started. A Sign-on screen...