  1. manersj

    merlin magix r2.1 how do i use winspm to assign busy indictor buttons

    how do i assign busy indicators on a 4412d+ phone using winspm
  2. manersj

    vodavi sts system

    a friend of mine asked me to look at his system to see if i could program it for ringing over the paging system at night i can set up the button for uda and it doesnt work after reading what docs hes got it says the trunks have to be programmed for UDA i can get into the programming port with my...
  3. manersj

    911 false trouble calls

    where in winspm do i go to set the timer lower so that it picks up the shorter calls since they are calling then hanging up i dont think the smdr would show it.
  4. manersj

    911 false trouble calls

    i dont know if it will record real short calls someones calling 911 and hanging up.
  5. manersj

    911 false trouble calls

    is there someway using spm to log all calls besides the smdr feature that would show all the calls being made from each ext. someone is pissed off and calling 911 and hanging up
  6. manersj

    kxtd 1232 ver3 with tvs100 intercept problem

    i set the trunk grp to intercept to ext 112 and after several rings it goes to ext 100 dont know why this is happening but need to find out why i had to dil the line 9 and 10 to the ext for it to work forward busy no answer is set to 165 which is the first voice mail port it works when i dil the...
  7. manersj

    adding 024 cards to an existing system

    whats the easiest way to move the 100dcd card if its not in use would it be better to delete the programming for the card then remove it and reboot the system. thanks again.
  8. manersj

    adding 024 cards to an existing system

    i have a two cabinet magix system that has the following POWER SUPPLY IS A 491E1 slot 0 processor CKE5 slot 1 412 LS-TDL slot 2 412 LS-TDL slot 3 024 TDL slot 4 016 TRR slot 5 100D/CSU/DSU-U CARRIER 2 POWER SUPPLY IS A 491D1 slot 6 Merlin Msg slot 7 024 TDL slot 8 412 LS-TDL slot 9...
  9. manersj

    restricting paging over a trunk on a merlin magix by station

    is there a way to program a button with the access code so that it dosent show when they press it that way i could program the buttons on the phones that need paging. (personal speed dialing or something like that)
  10. manersj

    restricting paging over a trunk on a merlin magix by station

    first i want to thank everyone for all their help. Is there anyway to keep station users from using the page feature in a class of service or something like that. the paging is going out over #9840 to a bogen ut1312 zone controller thaks guys again for all the help.
  11. manersj

    magix 3 paging using line position how do i set it up

    its a bogen paging system with a uti multizone paging unit so its loud speaker paging over the trunk port.
  12. manersj

    magix 3 paging using line position how do i set it up

    ive been reading the manuals but cant quite get it through my pea brain how to assign a button for using a trunk to page any help would greatly appreciated
  13. manersj

    Kxtd1232-4 with caller id question about log

    is there anyway to see the logs from anyother phone besides the Lowest Jack. the only info i found says the info is displayed on the lowest number jack.
  14. manersj

    adding a kx-td196 RMT card to a kx-td1232-3

    i cant find any info on programming this add-on card and or any documentation for it anyone have a copy that i cant use or can someone direct me to a site
  15. manersj

    merlin magix backup

    after i added two cards and renumbered them and changed group coverage etc. do i need to do a backup in order to keep the changes in case of a power failure or do the changes get saved when i exit the programming.