Does anyone have a Vodavi XTSc cabinet that I can purchase? I have a client site that is out of service and need this part yesterday.....
If you have one that you can part with, it would be most greatly appreciated.
You can contact me via cell at 423.593.3223
Thank you.............
Client has an NEC Elite IPK with CPUI(300)-U10, which originally had a PRI installed and worked flawlessly.
Client was talked into converting to a Dynamic IP SIP Trunking arrangement. Since the date of the installation, the system has had erratic behaviour, DID numbers terminating incorrectly...
Does anyone have the correct settings to make the Xiox Prophet H-3 call accounting system work with the SMDR output from an NEC Aspire?
Thank you in advance for your input!!!
Just a wild shot here but I have read where all Nortel IP sets have an internal watchdog timer.
The timer is defaulted at 200 seconds. It is reset by the TPS every 100 seconds and finally the display updates every 30 seconds.
If the IP set fails to acknowledge these or any other messages within...
OK team,
I try my best to only post unusual happenings. I need you guys input, so here goes.
1. Do Nortel VOIP phones support RSTP on the network? We have a flat network with no routing between the sites for this VLAN.
2. The VLAN that the VOIP phones is private to only the VOIP phones. We...
It's going pretty well, taking into account the database we were given. All in all, I believe we will survive.........
So, tek....where might you be these days?
B
Guys, I appreciate your top notch help on this. I actually have a couple of sites that are wanting this application.
Not only will I drink a few ales in your honor but I will remove my hat as well.
Thanks a million!!
I will test on my lab 11C before putting this in place. I will also cma by having a doc signed to release from any liability.
I will raise my ale glass in your honor this evening! Many, many thanks!
If anyone can provide me with insight as to a method to accomplish the following, I would be most appreciative.
Client needs to route 911 and 9911 calls to the security desk (internal extension). After the call is screened by security, local authorities will be notified by the security...
The correct part number is as follows;
NT9T6700 Small System Wallmount Bracket WPP= $41.00
J. Baron Ledford LVCU
Senior Project Engineer
Nu-Vision Technologies LLC
Georgia Offices
John,
The console was in place and had been working for well over a month before the failure occured, that is what strikes me as strange.
Just now we started the PEP installation and now it shows that file P18006D5 is corrupted and cannot be written to the directory on the PCMCIA drive. I have...
John,
Thanks for the info, somehow I knew that you would be one of the first to reply. Here is the kicker, the console is and has been locked up entirely. It has not been in service since it initially locked up. I guess I could out and rebuild to see if that restores it to service.