hi
i am tasked to look into vlan to secured my network. however the vlan have some IP to the production server. this is still not secured.
anyone hv any good approach to have private secured vlan (need to connect to selective production server) for visitor?
thks
Hi,
There is a parameter TDNS in LD23. The NTP description is not clear. Wonder if anyone can advise when to use "YES" and when to use "NO" in layman term.
========
Here is NTP description. "No" is the default value
TDNS-NO : DNIS number is not an original...
Hi,
How many level of password in Nortel PABX? Are there higher level of password than Level 1 and Level 2?
Does Nortel have a super password to all PABX?
Will there is a possibility to telnet into PABX via MAX IP address? How can it be acheive?
Thanks.
Hi,
In Nortel, there is a 4sec delay setting which will default the call to ACD (DFDN in CDN) if the host did not response to the call or route the call within 4sec.
Nortel claimed that the 4sec parameter cannot be changed. But I am hearing from alternate source that that 4sec timing can be...
Hi,
In Nortel, there is a 4sec delay setting which will default the call to ACD (DFDN in CDN) if the host did not response to the call or route the call within 4sec.
Nortel claimed that the 4sec parameter cannot be changed. But I am hearing from alternate source that that 4sec timing can be...
Hi,
Anyone using Mlink 5B (verion 5.05)? What is the different between 5B and 5C?
Genesys claimed that 5B have performance issue and recommend my site to upgrade to 5C. But 5C is EOL.
Pls advise.
Thanks.
Hi guys,
I am using Mlink version 5.05 (application version 6.03).
Is it M-Link 5, 5A, 5B, or 5C?
What shld be the exact version and application version for 5C?
Does anyone use Nortel with Genesys?
Hope someone can help.
Thanks.
Hi,
I am using xtalk software on my notebook. However, I realise that software does not support notebook internal modem. It only allow to interface with COM1. Hence I need to buy a external modem.
Even if it does allow to change com number, but it still does not work with internal notebook...
Our existing PABX rel 22.43, together with Mlink 5.05, does not support DTMF feature.
Why? Is it due to release version (if yes, which release support it) OR Nortel does not support it at all?
Appreciate reply from helpful sole.
Thanks.
Hi,
To put ISDN-2 on BRI card for Opt11C rel 22.43, do I use a NT (network terminator) box or use an ISDN-2 modem to interface with the telco provider ISDN-2 circuit (1 pair wire).
Thanks
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.