Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations wOOdy-Soft on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by killbox

  1. killbox

    PRI on prologix

    So I can just create the data modules? I'll have to find out to see if I can buy the feature. Thanks. Killbox
  2. killbox

    PRI on prologix

    I have a Definity Prologix Version 6. The customer wants to add a PRI. (Under System-Parameters, Customer-Options) It states ISDN PRI? N. What do I need to do to add a PRI? Can I just add a TN765 Processor Interface and create a data module? (Are there slots for this?) Do I need any licenses...
  3. killbox

    PRI not coming up

    I have the same situation as last, but it's a Prologix now? (I also just added a new post.) Can the same thing be done? Thanks. Killbox
  4. killbox

    PRI not coming up

    I gave one too!
  5. killbox

    PRI not coming up

    Thank you!!!!!!!!!!!!!!!!!!!! What a learning experience. I love it. Killbox
  6. killbox

    PRI not coming up

    Thank you so much. I really appreciate the help. Do I have to create all those data modules? Or just 1? Thanks. Killbox
  7. killbox

    PRI not coming up

    Yes, it only has 1 slot. It's a single carrier interface. So I put the card in, power up. Then just add data mod, comm link, and comm proc? Just pick the next available to add and my PRI and Signal Group will just work? Doesn't sound to complex. Never done that before, but I'm looking forward...
  8. killbox

    PRI not coming up

    LOL, yes not this old. (Can't paste. Programming on terminal and using clients PC.) With the below information from List Config Control, is there any other way, other than getting a new processor? (If I get a new processor, can I just do a restore of a back up and it will all come up?) THanks...
  9. killbox

    PRI not coming up

    Processor is a TN790B. Vintage 000005. V5 on it. There is a TN777B Network Control Inteface. V12 What can I do to get this to work? Killbox
  10. killbox

    PRI not coming up

    There are data modules set up in the system. Don't know why though? I took this site over. There is nothing on the system. Just 2 T1's, an old Audix. People make calls and receive. No features used. No perphial devices. Killbox
  11. killbox

    PRI not coming up

    Yes, it's working on their test set. Why would I have to progra a datamodule? Or comm link? I'm just creating a PRI? Killbox
  12. killbox

    PRI not coming up

    I've set up a million PRI's on Definity's. This one won't come up. The carrier has been to site and gone on the circuit with a test set. I've create and re-created the PRI. D Channel won't come up!! Group state - Out-of-service Level 3 state - manual-out-of-service No matter what slot...
  13. killbox

    Magix phones shorting each other out?

    How do you do that? If this is the problem, replace the cabinet/power supply? Thanks, Killbox

Part and Inventory Search

Back
Top