I'm seeing the same issue with SAV CE 8.00.9374, although if you go into the GUI, under File choosing Virus List, you will see the current DEFS date that are hopefully enabled.
If you have a NAI grant number they offer a installation designer for each of their VirusScan versions to make the kinds tweaks you are discussing in your post without the need to create a transform.
I am using Citrix Program Neighborhood 7.1 on Windows 2000 and Windows XP. I would like to know if there is an unattended script to add ICA connections to the Program Neighborhood.
Another thing...I noticed that when I manually removed VSC 7 and let ePO policies pull VSC 4.5.1 back down to the desktop, the ePO console reported on the machine that the Common Updater for VSC 7 was still installed even though VSC 4.5.1 was back on the machine. Does any one know how to remove...
I've had the issue on two machines:
-Compaq Evo D510 SFF 2.4 XP SP1
-Compaq Evo N600 1.2 WIN2K SP3
All I've been able to do in the mean time is delete VSC 7 and let the ePO agent pull VSC 4.5.1 SP1 back down.
The only thing I have been able to conclude so far was that the two machines I've had...
I have an issue while in the VirusScan Console, I choose the AutoUpdate task, click on the start button in the toolbar and whamo I get the following error:
"Failed to initialize Common Updater subsystem. Make sure the McAfee Framework Service is running"
Thanks in advance
Have you tried to copy those report queries from:
C:\Program Files\McAfee\ePO\2.0\AVI\0409 on a working machine to the machine that has the corrupt queries
I would suggest trying a Wake-Up Call using the Full Properties option. If that doesn't fly delete or rename the fullprops.ini file and try the wake-up call with Full Properties option to generate the new fullprops.ini
I'm rolling out Altiris and would like to use ePO to push out the Altiris NS client. If I package the client into an .exe and name it setup.exe with the two McAfee files (forget the names) into a folder and run an upgrade task...would it work??
BTW it runs silently
Two questions:
1. When ask to enter credentials to pull from master repository into Novell \\UNC share I keep receiving bad credentials. Not sure what format its looking for since its asking for a Domain instead of Novell Tree context.
2. Is there any way to schedule replication tasks to...
When updating the agent patch for ePO 2.5.1 buffer issue to remote sites with limited bandwidth (256kb - 512kb / 100 node site) is it better to proactively configure the ASC interval to 4-5 days and selectively send wake-up calls to machines to upgrade. Or do you just limit concurrent downloads...