I am trying to use Internet Explorer to log into our new G430 MG. I'm at the part where it states "Enter SNMP paramters" and it states SNMPv1 and the field states "Community". Does anyone know what I need to put in this field?
Thank you!!
Hi Everyone,
We just upgraded to Symposium 4.2, could anyone send me the Scripting manual? Our vendor providedus with Amin. manuals, but it contains very little info about Symposium Script writing.
Thanks alot!!
Email = sserwin@yahoo.com
Hi Everyone,
We just upgraded to Symposium 4.2, could anyone send me the Scripting manual? Our vendor providing Amin manuals, but it contains very little info about Symposium Script writing.
Thanks alot!!
Email = sserwin@yahoo.com
You need to see what RLI 866 is using. In LD 90, do:
REQ PRT
Cust 0
FEAT NET
TRAN AC1
TYPE NPA OR SPN [depends what you programmed 866 as]
This will show RLI = ?
Then you need to go to Ld 86 to determine what routes are first choice for that RLI. In LD 86, do
REQ PRT
CUST 0
FEAT RLB
RLI...
LD 96
.STAT DCH 7
DCH 007 : DSBL RST AUTO BKUP 009
DES : Qwest2Pri
LD 17
REQ CHG
TYPE ADAN
ADAN OUT DCH 7
SCH5589 [cannot out application from MSDL card, as this is the last application]
ADAN
I already have the Dch diabled in LD 96, I am trying to out it in LD 17 but keep...
I am trying to do a change. I am now trying to out the Dch and rebuild. How do you disable an MSDL card? I have the d-ch disabled in LD 96, but I need to disable the MSDL card before I can out it in LD 17.
Thanks.
I am trying to configure a PRI in an Opt 81. In LD 17 [ADTRAN], for IFC, I am trying to use NI2, but I get a SCH 6357. This translates to "interface change is not allowed for UIPE D-channels"?
Does anyone have an idea what this means? What is an UIPE D-channel? Is there anyway...
I connected a new CDR App to my Opt 11 [Microcall] but noticed it is not tracking DN to DN calls [internal ext to ext calls]. I checked the CDR in LD 15 and ADAN, but did not see anything that will allow this. Any ideas as to how to allow the tracking of DN to DN calls for CDR?
Thank you...
I inherited an Opt 81 where all the area codes are built as SPNs [instead of 1201, it's built as 12]. So, I received an assignment to block 555 [directory assistance] for all SPNs. In order to do that, for example, for SPN of 12, I need to deny 01555 [which denies 555 for area code 201], 02555...
ACE,
MXSD expands the number of SDR blocks [I said ports before, I meant to write blocks]. SDR stands for Supplemental Digit Restriction. This controls the total number of SPNs and/or NPAs that your PBX is able to have programmed at any one time. If you try to add an NPA or SPN and receive...