Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Wanet Telecoms Ltd on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by HelpTheWestie

  1. HelpTheWestie

    PP8600 R Module ACL

    Hi I have set-up an ACL filter from VLAN1 to VLAN3. This filter drops any traffic going to VLAN3, which i have working. But when i try allowing one host address from VLAN1 to VLAN3 it is still getting blocked.... Can anyone point my in the right direction?? filter act 1 create name "Vlan...
  2. HelpTheWestie

    Baystack 5510 port mirroring

    Do you know when Verison 5.0 is due out?? Are Nortel increasing the number of MLT in this Version?? Thanks Help The Westie
  3. HelpTheWestie

    PP8600 R Module ACL

    Hello, Has anyone set-up an ACL Filter using the New 8630GBR modules?? I'm Running Software Version 4.0.5 I'm trying to block/filter any Ping traffic from my default VLAN1 to my Voice Vlan3.... I'm using device manager and i'm getting very lost!! Any help would be great Help The Westie
  4. HelpTheWestie

    Baystack 5510 port mirroring

    Antonyanderberg Thankyou for the above post, I have got port-mirroring mode Many-to-one working using Software 4.3…But, I’m unable to find any release note on this new feature, Arrrrr Nortel doc’s?? Help the Westie
  5. HelpTheWestie

    ERS 8600 Error MSG

    The chassis boot up. When looking at the Show Tech Info i'm not getting any info for the first power supply... So i'm guesting that may be the problem, but why i don't know?
  6. HelpTheWestie

    Baystack 5510 port mirroring

    Jonks Are you able to test theses two devices on a Baystack 450 switch?? and all ports running at the same speed/duplex?? Regards
  7. HelpTheWestie

    ERS 8600 Error MSG

    Hi I’m getting the following error msg when booting my Passport (ERS) 8610 seepromGetInfo: crc failed on device 20, calc: efde dev: f0de Hardware: Chassis 8610 1* 8692 SF in Slot 6 1* 8630GBR in Slot 2 Software: 4.0.5.0 Any pointers or help would be great Regards Russell
  8. HelpTheWestie

    Second Switch Fabric / SMLT

    We are now running software version 3.7.8. For a week i ran an SMLT network with two Passport 8610 with one Switch Fabric installed in both chassic. We have 9 SMLT Switch Stacks 3*450's, 6*5510/5520's. The SMLT network was fine all week. When pinging the interfaces/VRRP addresses of the...
  9. HelpTheWestie

    Second Switch Fabric / SMLT

    Hi We are not running L2/L3 HA Mode. I have switched the CPU blades and we still get the packet incresses.
  10. HelpTheWestie

    Second Switch Fabric / SMLT

    In total we have 3 * 450's stacks. We have 5 Vlan's and our VRRP VRID are 15, 16, 17, 18, 19. But why does it only happen when both Second Switch Fabrics are installed?
  11. HelpTheWestie

    Second Switch Fabric / SMLT

    Hello Please can anyone help with the below problem... We are run 2 Passport 8010 with two Switch Fabric Model 8691SF with 256 MB. We are running an SMLT network with 5510/5520 and 450 Switch stacks. Here is the problem... When both passports are running on one Switch Fabric the network is...
  12. HelpTheWestie

    CES 251 to CES 1600

    After 2 weeks and alot of playing it is working!! By using the log on the 251 i was able to enter the right Peer ID Values Thanks for your help biv343
  13. HelpTheWestie

    CES 251 to CES 1600

    You have got the question correct. Here are my setting for the ces 1600 Encryption: - ESP - Triple DES with SHA1 Integrity: Enabled IKE Encryption and Diffie-Hellman Group: Triple DES with Group 2 (1024-bit prime) Vendor ID: Enabled Aggressive Mode ISAKMP Initial Contact Payload: Disabled...
  14. HelpTheWestie

    CES 251 to CES 1600

    Hi Help.... I have a Contivity 251 and a Contivity 1600. I'm trying to set-up an IPsec tunnel. The Contivity 251 is the initiator, and does not have a static IPaddress. The Contivity 1600 is the responder. How can i set-up the contivity 251 to use a different source address when creating the...
  15. HelpTheWestie

    PP8600 Error Msg after upgarding to 3.7.7

    All I have answer my own question rcSysAction.0: nonWritable Is down to running the wrong version of Device Manager... I was running version 5.8.5.0 - Passport 8600 version 3.7.7 need device Manager 5.8.8.0 Ta All

Part and Inventory Search

Back
Top