Standard NI2 – We’re taking all the calls and just passing them through to the PBX, no special routing for DIDs that are part of the PRI."
This is the reply back from telco to your question
It will be next week until I am back onsite to run the reports requested.
I am in the middle between...
I made a typo, long story but I had to retype output of report.
CTYP MSDL is the current setting
So you are suggesting we change BSERV to NO ?
I believe a couple of providers ago , we had several call paths over different networks depending on in state out of state international etc.
KCFLHRC here is the print out of the 2 d-channels I appreciate your time and help.
ADAN DCH 0
CTYP MSDC
DNUM 10
PORT 2
DES GLOBAL_ACCESS
USR PRI
DCHL 18
OTBF 32
PARM RS422 DTE
DRAT 64KC
CLOK EXT
IFC NI2
ISDN_MCNT 300
CLID OPT0
CO_TYPE STD
SIDE USR
CNEG 1
RLS ID **
RCAP COLP
T310 120
T200 3...
KCFLHRC
Do the following two statements mean anything to you as far as the adtran configuration is concerned?
[highlight #EF2929]Switch Engineer[/highlight]
The report back from the switch engineer says that "the far end dch isn't sending the restart all channels command, Our switch is set...
We are having problems after switching telcos, the new telco is providing 2 PRI via an adtran 908e and we are having intermittent call failures both inbound and outbound.
Any ideas of what to tell telco to change to make this work properly?
Greg D