  1. gndsystems

    Can not enable dch

    I can not get dch enabled Ld 96 stat gives dch 000 dsbl rst Also get an error 0000086 Thanks
  2. gndsystems

    Adtran 908e and CS1000 PIR problem

    KCFLHRC TYPE TLIST TKTP DID ROUT 0 DES GLOBAL_ACCESS TN 018 01 MBER 1 GLOBAL_ACCESS TN 018 02 MBER 2 GLOBAL_ACCESS TN 018 03 MBER 3 GLOBAL_ACCESS TN 018 04 MBER 4 GLOBAL_ACCESS TN 018 05 MBER 5 GLOBAL_ACCESS TN 018 06 MBER 6 GLOBAL_ACCESS TN 018 07 MBER 1 GLOBAL_ACCESS TN 018 08 MBER 8...
  3. gndsystems

    Adtran 908e and CS1000 PIR problem

    Standard NI2 – We’re taking all the calls and just passing them through to the PBX, no special routing for DIDs that are part of the PRI." This is the reply back from telco to your question It will be next week until I am back onsite to run the reports requested. I am in the middle between...
  4. gndsystems

    Adtran 908e and CS1000 PIR problem

    I made a typo, long story but I had to retype output of report. CTYP MSDL is the current setting So you are suggesting we change BSERV to NO ? I believe a couple of providers ago , we had several call paths over different networks depending on in state out of state international etc.
  5. gndsystems

    Adtran 908e and CS1000 PIR problem

    KCFLHRC here is the print out of the 2 d-channels I appreciate your time and help. ADAN DCH 0 CTYP MSDC DNUM 10 PORT 2 DES GLOBAL_ACCESS USR PRI DCHL 18 OTBF 32 PARM RS422 DTE DRAT 64KC CLOK EXT IFC NI2 ISDN_MCNT 300 CLID OPT0 CO_TYPE STD SIDE USR CNEG 1 RLS ID ** RCAP COLP T310 120 T200 3...
  6. gndsystems

    Adtran 908e and CS1000 PIR problem

    KCFLHRC Do the following two statements mean anything to you as far as the adtran configuration is concerned? [highlight #EF2929]Switch Engineer[/highlight] The report back from the switch engineer says that "the far end dch isn't sending the restart all channels command, Our switch is set...
  7. gndsystems

    Adtran 908e and CS1000 PIR problem

    We are having problems after switching telcos, the new telco is providing 2 PRI via an adtran 908e and we are having intermittent call failures both inbound and outbound. Any ideas of what to tell telco to change to make this work properly? Greg D