Hi DEP lists are installed. I found the problem. The DASS Routes had LID set to 0 ie not sending CLID. Changed LID to 1 so now i/c calls on the DASS routes now pass the CLID over onto the Q931 Circuits. As part of the upgrade the NTAK35 DASS/DDSL cards had to be changed for NT6D11 DCHI cards...
Here you go John
Cheers
Dave
ld 21
PT1000
REQ: prt
TYPE: rdb
CUST 0
ROUT 5
TYPE RDB
CUST 00
ROUT 5
DES
TKTP TIE
NPID_TBL_NUM 0
ESN NO
RPA NO
CNVT NO
SAT NO
IDEF NET
RCLS INT
VTRK NO
NODE
DTRK YES
BRIP NO
DGTP PRI2
ISDN YES
MODE PRA
IFC SL1
PNI 00701
NCNA YES
NCRD...
Hi Guys
Recently upgraded option 61c from 25.15 to 4.5.
All is fine apart from an issue with CLID,
A call is made into the switchboard on the upgraded 61c the clid (ie my mobile no. is shown on the console display, if the call is then transfered over a Q931 circuit to another option 61c all...
It depends on how far away the consoles are from the Option 11 . If in excess of 50 metres you will probably need the power TNs . If less than 50m you should be ok without them and therefore you could use the TNs for digital sets