Hey, I set up some Polycom 6000's on my SV8100, and took some notes when I did it.
I have 4-digit extensions, my Polycom's are all 4-digit extensions, and I have never had any problems.
My notes say that I use 4.06 firmware
I also use a custom bootrom that I made...I think I just display the...
How did you send the diagram? I dont see it.
OK, so in my case, the RCA jack from CH1 is going to go to the amplifier. That makes perfect sense.
I'll install a digital station jack on the wall next to the phone switch, and verify that a phone works when plugged into it. Then we'll go from...
How did you send the diagram? I dont see it.
OK, so in my case, the RCA jack from CH1 is going to go to the amplifier. That makes perfect sense.
I'll install a digital station jack on the wall next to the phone switch, and verify that a phone works when plugged into it. Then we'll go from...
I have a branch office that is NetLink'd to the the home office.
I have 2 POTS/CO lines at the branch office, and I need to disconnect them.
Can I point a DID at the home office to an extension at the branch office? I know how to, I just haven't tested it yet.
More importantly, how can I get...
From the manual:
Installing an External Page System
1. Connecting to the CD-CP00-US:
Connect an RCA line from the CN8 or CN9 connector on the CD-CP00-US to the appropriate location on the extension cross-connect block.
2. Connect the two-conductor station cable from the cross-connect block to...
I need some help installing an external paging system.
I read the SV8100 System Hardware Manual on the PGD(2)-U10 ADP and I am tad bit confused.
I have a functioning overhead paging system now, but its not hooked to the phone system.
It consists of overhead speakers, an amp, and a mic.
I...
I finally figured out the problem.
I had incorrectly added @@@5551212 in the wrong area in an effort to keep employees from calling AREA-CODE+555-1212.
When I did this, the system still allowed 7 and 10 digit dialing, but not 3 digit dialing.
I got it all working.
I am routing 911 calls for specific set of VOIP extensions to go out the Verizon device.
I also remembered to configure the switch so that if the 911 dispatch center calls back, it will ring on all the voip phones.
I know what you are saying about them not being true POTS lines, and at first I thought you might be right, because one of the sites is a Windstream fiber circuit that has Dynamic IP lines (SIP-to-POTS), but the other sites have the same problem, and they are other carriers.
I know the carrier...
I forgot to mention...I have an issue with getting 911 out on that trunk.
If I dial, #9, 028, I can dial local and l/d just fine, but as soon as I dial 911 it jumps to port 23.
I don't know why it jumps like that.
How can I stop that from happening?
System: SV8100
At my main site, I have a PRI and I can dial 9,511 or 9,611 just fine. I can also call either 9,911 or 911 just fine. Everything normal here.
The problem is at my branch offices where they have CO/POTS trunk lines.
When they dial 911, or 9,911, or 9,511 or 9,611 type numbers...
I like your idea of a button for 911.
You're right about ARS - I have been messing with the simulator, think I have it, then it just flat out doesn't do what I expect it to do!
Can I do a speed dial button that does: #9,028,911 ?
This way, they dont even need to dial 911, the single press of a...
I have a remote branch office with just 5 phones - NEC VOIP phones that are registered to the SV8100 at my main site.
Obviously, when these phones call 911, the wrong address is received by 911 responders.
I have been trying to get a SIP trunk built between the SV8100 and a Grandstream HT503...