It worked after I went and did as RS528 said.
ESN 125 means "Undefined CDP type (LSC, DSC, TSC, ALL)."
Goto LD 86 print and change the prompt:
CDP (YES) NO Coordinated Dialing Plan feature for this customer
- MXSC 0-5000 Maximum number of Steering Codes
- NCDP 3-7 Number of digits in CDP DN...
I get this:
Ld 87
req chg
cust 0
feat cdp
type dsc
dsc number you wish to send to other switch
esn125
ESN125 after I have tried to push the number to the other switch. I will try building another route on the tie line then give it another try.
Thanks for you guys input.
Fizer
I have to send 18 Dn's from a Nortel 61C across a tie line to an 11C. I have attempted this in Load 87 but have not had any luck. I have made a test phone on the 61C to see if it would Transfer to the 11C via the tie line. It did not work. I also outed the test phone on the 61C thinking maybe it...
Thank you all for your help. I understand what your saying. I have the tie line alrady programmed and the connection is there all I have remaining is to make changes to the phones as you said pointing them to the mwi FDN and then building them on the call pilot.
Thanks again,
I was able to do an ini and the switch let me in to work on the Merdian Mail. It is now back up and working. Thanks to all of you for your assistance and support.
I need to connect our call pilot voice mail from main site which is a 61C to remote location where we have an 11C installed. We have a tie line running to the main site (61C) from the (11C). Currently the 11C voice mail crashed (Merdian Mail 13) and I want to just combine the two switches so I...
The TTY are all ok. And to answer your question the Merdian Mail does not respond to load 48 after I typed in the commands to disable and then re-able the aml link. The next thing I will try is the INI of he system tommorrow. I am in Korea so I do not get a chance to talk to any of you due to...
I have an 11C with an expansion cabinet. They are connected together with fiber. The voice mail used is the Merdian Mail 13 which is located in slot 10 of cabinet one. The other day I noticed the Merdian Mail was not working. I checked out the MAT 6.67 and also found it to be dead (as I tried to...
I have logged out of the application and then ran my disk defrag then went back into the system and the problem went away. The software tends to have a hay day on the disk because it is such a large application as Jonh Poole stated.
I have to install three new IVG lines into a Merdian 61C. I have no clue on what I need to do. I went into the loads and found that there are currently five IVG circuits located on route 30 already and they want me to add three more. I know I have to program them in but not sure how and what...
I had the PC based program you are talking about when I arrived at the work site and after a week removed it. I learned the operators had nothing but problems and switched back to the 2250. Like it was said in earlier briefs the system has to be rebooted too much.
I just went through this. MAT will only install on 98 second edition and NT. I am upgrading to OTM and have to use service pack 3 along with selecting the ILLS in the software selection of my computer before you install the OTM.
OK. Looks like all the attempts have failed so I am going back to just using the overlay and work directly out of the switch like johnpoole mentioned. Its a lot more work but I will know the switch much better. Thanks again everyone.
Fizer
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.