Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Wanet Telecoms Ltd on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by espen19

  1. espen19

    TelStrat T1/IPE interface box between SL100 and IPE remote shelf

    SL100 is the big brown cabinets and the IPE shelf is a Meridian shelf like off of an 81c. The interface card, I am talking about is not part of either system. It is a Telstrat device that has 4 lights on the front Power, MTC, red alarm and yellow alarm along with 4 ports for RJ45 connectors to...
  2. espen19

    TelStrat T1/IPE interface box between SL100 and IPE remote shelf

    Thank you for your reply. I have verified dip switches each time I have switched them out. ON my host end, switch 3 is on and on my remote end, switches 2 and 3 are on with everything else off.
  3. espen19

    TelStrat T1/IPE interface box between SL100 and IPE remote shelf

    I have an SL100 with an IPE shelf remote. I have 2 LGC links going to the T1/IPE interface (Host) to a T1/IPE interface (remote) to the IPE shelf. Last Tuesday, the IPE shelf dropped. No power outage or weather caused this. I had no alarms on the T1/IPE interface cards which is odd because...
  4. espen19

    General PBX question

    I never looked there. I will check that. Thank you.. It is the same as the nortelid that I gave him. I appreciate the help...
  5. espen19

    General PBX question

    I gave him the software version which is MSL10BM. I gave him the site ID, but he keeps insisting on software licenses...
  6. espen19

    General PBX question

    I appreciate it. I never heard about it, but I am sure since they exist on other old switches, that they also do on this one. Thank you again for your help...
  7. espen19

    General PBX question

    I do have an SL100. It was installed in 1987 and software release is MSL10BM. It hasn't been updated in a very long time... What Serial Number are you talking about and where would I get it from??Thank you for the response...
  8. espen19

    General PBX question

    Is anyone aware of software licensing on just a regular old PBX like an SL100? I have never heard of anything like it on a PBX, but a guy that is doing a survey for pricing to go IP here on our site is adamant that there is software licensing on this old switch and he can get cost savings...
  9. espen19

    SL 100 Question

    both loaded from CC this morning. Still have the alarm....
  10. espen19

    SL 100 Question

    yeah. dial tone is available and each unit has been reloaded. I appreciate your help..
  11. espen19

    SL 100 Question

    none are exceeded. I fixed all of my issues in almstat the other day while trying to figure this out. I am not sure what this alarm is.
  12. espen19

    SL 100 Question

    WHen I do the querypm flt, it just shows LCM unit 0 insv and LCM unit 1 insv. no fault shows up.
  13. espen19

    Octel 350 using NetTerm

    How do I define a break key using Netterm? When I log into my SL100, I send a break with Ctrl + pause/break... When I try that using Netterm logged into the Octel 350, I get invalid character. Any help would be greatly appreciated.
  14. espen19

    SL 100 Question

    I have an Line alarm, but when I go into LNSTRBL, if gives me no information other than I have a critical alarm in LCM 3-0. I have gone back through logutil but can't find any info. Where would I find the issue here? Thank you for any help you can provide...

Part and Inventory Search

Back
Top