Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations derfloh on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by EMJP

  1. EMJP

    ncp500 no voice

    Increase the UDP timeout in your router + 180 seconds minimum?
  2. EMJP

    Panasonic KX-NT546/543

    I never had any problems with V2.01, are you sure the file is not corrupted? What model of Panasonic PBX do you have and what version? The PBX must also be a compatible version.
  3. EMJP

    "Integrate Panasonic TDE100 PBX mikrotik

    The solution is to create a dual WAN in the router. One WAN for SIP and one for data; the Panasonic keeps its LAN IP address. I used to do this regularly, but not with Microtik. Wan1 = Internet accès WAN2 = SIP
  4. EMJP

    KX-TDE100 Canada last firmware and Maintenance console

    I only have NE (North Europe) versions. However, if you're interested, I have a crack for Pana passwords. TDA TDE NCP, really safe, I've been using it for over 10 years. You have to choose the country code at first startup; for example, for me, it's NE/BE. For licenses, send me a request in a...
  5. EMJP

    Panasonic KX-DTA600 call forward

    Is the phone the only recipient of incoming calls on this analog line ?
  6. EMJP

    Firmware KX-NT551

    The PBX receives VLAN settings only from the connected switching hub. Therefore, VLAN settings for the PBX must be assigned at the switching hub. You need to declare the VLAN in which your phone's primary Ethernet port is located, so you leave the phone in DHCP. The code to access the phone's...
  7. EMJP

    Firmware KX-NT551

    Your problem is quite simple: with the phone on the hook, press the "MUTE" button. If it is lit (red LED), you are in automatic answer mode. If it is off, the phone rings (this is only for internal calls). Or check that forced automatic answer is disabled! (Off)
  8. EMJP

    Firmware KX-NT551

    Select the target to update Apply / execute attached: PNT550 latest version (for NT55X) (ZIP)
  9. EMJP

    Change display language on NT NS1000UK phones

    For a while I received NS700/1000 UK version, to switch the phone displays to French I used this (included instructions and multi-language files) (NS700 NE)
  10. EMJP

    ns1000 password for CA

    https://www.tek-tips.com/threads/communications-assistant-client-password-reset.1819553/
  11. EMJP

    PANASONIC kx-tde 100

    Agitel is not very explicit, it does not say if the IP phones are internal, or external, or if it uses SIP access
  12. EMJP

    PANASONIC kx-tde 100

    You need to disable SIP ALG in your router
  13. EMJP

    ns1000 clock

    With the operator's phone: set date and time program *#1234 ' 1234 or configured PIN (I don't remember if it's *# or #*) but 1234 is the default PIN; it can be changed in the program
  14. EMJP

    sip ext ncp500

    I can activate licenses for NCP; just send me the NCP credentials in a private message. Are you the same CTAMIR as on the Grandstream Forum?